{"info":{"_postman_id":"6375289a-c484-476a-8f8e-b02a7053ecd0","name":"capacity","description":"<html><head></head><body><p>The Capacity API is used by facility operators and trading participants to submit and receive data relating to capacity trades and day ahead auction for AEMO’s Capacity Transfer Platform (CTP) and Day-Ahead Auction (DAA) market systems.</p>\n</body></html>","schema":"https://schema.getpostman.com/json/collection/v2.0.0/collection.json","toc":[],"owner":"10032049","collectionId":"6375289a-c484-476a-8f8e-b02a7053ecd0","publishedId":"2s93CNNDaF","public":true,"customColor":{"top-bar":"FFFFFF","right-sidebar":"303030","highlight":"EF5B25"},"publishDate":"2023-02-24T05:16:38.000Z"},"item":[{"name":"postAuctionQuantities","id":"8fd305ce-3a0e-418d-b0a4-c56b120d154d","protocolProfileBehavior":{"disableBodyPruning":true},"request":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"<p>The ID of the Initiating Participant</p>\n"},{"key":"X-market","value":"GAS","description":"<p>The market type that the request applies.</p>\n"},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionDate\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"FacilityId\": 530001,\r\n    \"LimitId\": 3001,\r\n    \"LimitQuantity\": 230,\r\n    \"TransitionalRightsQuantity\": 120,\r\n    \"OperationalOverride\": \"YES\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionQuantities","description":"<p>Provide the auction quantities available for the day ahead auction. A submission may include one or more facilities. A full set of product components must be provided for each facility included in a submission. For example, if two facilities are included in one submission, one facility has a full set of limits specified and the other does not, the entire submission will be rejected. If multiple submissions are received by AEMO, the data received in the latest submission for each facility prior to the cut-off time is used as input into the auction.</p>\n","auth":{"type":"basic","basic":{"basicConfig":[]},"isInherited":true,"source":{"_postman_id":"6375289a-c484-476a-8f8e-b02a7053ecd0","id":"6375289a-c484-476a-8f8e-b02a7053ecd0","name":"capacity","type":"collection"}},"urlObject":{"path":["auctionQuantities"],"host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"query":[],"variable":[]}},"response":[{"id":"5ac8517c-2d75-4a4a-9636-8c9482d84492","name":"Response_500","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionDate\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"FacilityId\": 530001,\r\n    \"LimitId\": 3001,\r\n    \"LimitQuantity\": 230,\r\n    \"TransitionalRightsQuantity\": 120,\r\n    \"OperationalOverride\": \"YES\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionQuantities","description":"Provide the auction quantities available for the day ahead auction. A submission may include one or more facilities. A full set of product components must be provided for each facility included in a submission. For example, if two facilities are included in one submission, one facility has a full set of limits specified and the other does not, the entire submission will be rejected. If multiple submissions are received by AEMO, the data received in the latest submission for each facility prior to the cut-off time is used as input into the auction."},"status":"e-Hub is operational but downstream systems are not available.","code":500,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"bbabadf5-4ab4-4e97-b5c0-4876ba196deb","name":"Response_503","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionDate\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"FacilityId\": 530001,\r\n    \"LimitId\": 3001,\r\n    \"LimitQuantity\": 230,\r\n    \"TransitionalRightsQuantity\": 120,\r\n    \"OperationalOverride\": \"YES\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionQuantities","description":"Provide the auction quantities available for the day ahead auction. A submission may include one or more facilities. A full set of product components must be provided for each facility included in a submission. For example, if two facilities are included in one submission, one facility has a full set of limits specified and the other does not, the entire submission will be rejected. If multiple submissions are received by AEMO, the data received in the latest submission for each facility prior to the cut-off time is used as input into the auction."},"status":"Exceeds throttling limits OR SSL Certificate authentication validation failed","code":503,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"651e0e76-f90d-4306-bb64-3e0657e3f993","name":"Response_400","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionDate\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"FacilityId\": 530001,\r\n    \"LimitId\": 3001,\r\n    \"LimitQuantity\": 230,\r\n    \"TransitionalRightsQuantity\": 120,\r\n    \"OperationalOverride\": \"YES\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionQuantities","description":"Provide the auction quantities available for the day ahead auction. A submission may include one or more facilities. A full set of product components must be provided for each facility included in a submission. For example, if two facilities are included in one submission, one facility has a full set of limits specified and the other does not, the entire submission will be rejected. If multiple submissions are received by AEMO, the data received in the latest submission for each facility prior to the cut-off time is used as input into the auction."},"status":"The service cannot be found for the endpoint reference (EPR) <URI>","code":400,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"f96ee63f-9789-4587-8d3c-af3a410b5b03","name":"Response_404","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionDate\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"FacilityId\": 530001,\r\n    \"LimitId\": 3001,\r\n    \"LimitQuantity\": 230,\r\n    \"TransitionalRightsQuantity\": 120,\r\n    \"OperationalOverride\": \"YES\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionQuantities","description":"Provide the auction quantities available for the day ahead auction. A submission may include one or more facilities. A full set of product components must be provided for each facility included in a submission. For example, if two facilities are included in one submission, one facility has a full set of limits specified and the other does not, the entire submission will be rejected. If multiple submissions are received by AEMO, the data received in the latest submission for each facility prior to the cut-off time is used as input into the auction."},"status":"This response is provided when the resource is missing from the URL or the URL is incorrect.","code":404,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"c6eeb138-6359-4175-aa33-293b5833081b","name":"Response_403","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionDate\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"FacilityId\": 530001,\r\n    \"LimitId\": 3001,\r\n    \"LimitQuantity\": 230,\r\n    \"TransitionalRightsQuantity\": 120,\r\n    \"OperationalOverride\": \"YES\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionQuantities","description":"Provide the auction quantities available for the day ahead auction. A submission may include one or more facilities. A full set of product components must be provided for each facility included in a submission. For example, if two facilities are included in one submission, one facility has a full set of limits specified and the other does not, the entire submission will be rejected. If multiple submissions are received by AEMO, the data received in the latest submission for each facility prior to the cut-off time is used as input into the auction."},"status":"This response is provided when there is an invalid Role i.e. user does not have permission to submit this request.","code":403,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"05fc8443-6eb7-4d47-8ac9-e8e2975f261c","name":"Response_422","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionDate\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"FacilityId\": 530001,\r\n    \"LimitId\": 3001,\r\n    \"LimitQuantity\": 230,\r\n    \"TransitionalRightsQuantity\": 120,\r\n    \"OperationalOverride\": \"YES\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionQuantities","description":"Provide the auction quantities available for the day ahead auction. A submission may include one or more facilities. A full set of product components must be provided for each facility included in a submission. For example, if two facilities are included in one submission, one facility has a full set of limits specified and the other does not, the entire submission will be rejected. If multiple submissions are received by AEMO, the data received in the latest submission for each facility prior to the cut-off time is used as input into the auction."},"status":"This response is provided when any there are any Business validation failures, then entire submission is rejected.","code":422,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"8dd0faa6-817b-4e08-8e58-5f01e8aecf9b","name":"Response_401","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionDate\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"FacilityId\": 530001,\r\n    \"LimitId\": 3001,\r\n    \"LimitQuantity\": 230,\r\n    \"TransitionalRightsQuantity\": 120,\r\n    \"OperationalOverride\": \"YES\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionQuantities","description":"Provide the auction quantities available for the day ahead auction. A submission may include one or more facilities. A full set of product components must be provided for each facility included in a submission. For example, if two facilities are included in one submission, one facility has a full set of limits specified and the other does not, the entire submission will be rejected. If multiple submissions are received by AEMO, the data received in the latest submission for each facility prior to the cut-off time is used as input into the auction."},"status":"This response is provided when \"Authorisation\" is missing from the header OR user/password is incorrect/not provided OR user account is locked out.","code":401,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"bf9f5131-725c-4d65-858c-4e56ceeaeb2f","name":"Response_405","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionDate\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"FacilityId\": 530001,\r\n    \"LimitId\": 3001,\r\n    \"LimitQuantity\": 230,\r\n    \"TransitionalRightsQuantity\": 120,\r\n    \"OperationalOverride\": \"YES\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionQuantities","description":"Provide the auction quantities available for the day ahead auction. A submission may include one or more facilities. A full set of product components must be provided for each facility included in a submission. For example, if two facilities are included in one submission, one facility has a full set of limits specified and the other does not, the entire submission will be rejected. If multiple submissions are received by AEMO, the data received in the latest submission for each facility prior to the cut-off time is used as input into the auction."},"status":"Invalid Method used (e.g. GET used instead of POST)","code":405,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"007c9aa2-d569-4d35-a2e6-a62976d3a47b","name":"Response_411","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionDate\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"FacilityId\": 530001,\r\n    \"LimitId\": 3001,\r\n    \"LimitQuantity\": 230,\r\n    \"TransitionalRightsQuantity\": 120,\r\n    \"OperationalOverride\": \"YES\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionQuantities","description":"Provide the auction quantities available for the day ahead auction. A submission may include one or more facilities. A full set of product components must be provided for each facility included in a submission. For example, if two facilities are included in one submission, one facility has a full set of limits specified and the other does not, the entire submission will be rejected. If multiple submissions are received by AEMO, the data received in the latest submission for each facility prior to the cut-off time is used as input into the auction."},"status":"This response is provided when \"Content-Length\" is missing from the Header","code":411,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"bc047d26-8288-4432-b062-a054a3f71768","name":"Response_200","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionDate\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"FacilityId\": 530001,\r\n    \"LimitId\": 3001,\r\n    \"LimitQuantity\": 230,\r\n    \"TransitionalRightsQuantity\": 120,\r\n    \"OperationalOverride\": \"YES\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionQuantities","description":"Provide the auction quantities available for the day ahead auction. A submission may include one or more facilities. A full set of product components must be provided for each facility included in a submission. For example, if two facilities are included in one submission, one facility has a full set of limits specified and the other does not, the entire submission will be rejected. If multiple submissions are received by AEMO, the data received in the latest submission for each facility prior to the cut-off time is used as input into the auction."},"status":"Successful","code":200,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""}],"_postman_id":"8fd305ce-3a0e-418d-b0a4-c56b120d154d"},{"name":"postAuctionSettlementQuantities","id":"42f1cff2-1ed8-4bf3-957f-a8ffba5df409","protocolProfileBehavior":{"disableBodyPruning":true},"request":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"<p>The ID of the Initiating Participant</p>\n"},{"key":"X-market","value":"GAS","description":"<p>The market type that the request applies.</p>\n"},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionTransactionId\": 10001,\r\n    \"RevisedAuctionQuantity\": 100,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"FinalScheduledQuantity\": 100\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionSettlementQuantities","description":"<p>Provide the actual auction quantities and final nominations after the end of each gas day.\nThis information is required by AEMO for settlement purposes.</p>\n<p>If multiple submissions are received by AEMO, the data received in the latest submission prior to the cut-off time is used for indicative or final settlements.</p>\n<p>Auction quantity is used for settlements if data is not received by the cut-off time</p>\n","auth":{"type":"basic","basic":{"basicConfig":[]},"isInherited":true,"source":{"_postman_id":"6375289a-c484-476a-8f8e-b02a7053ecd0","id":"6375289a-c484-476a-8f8e-b02a7053ecd0","name":"capacity","type":"collection"}},"urlObject":{"path":["auctionSettlementQuantities"],"host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"query":[],"variable":[]}},"response":[{"id":"b19b9706-99ec-4c0d-bc13-536e597fe8e4","name":"Response_503","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionTransactionId\": 10001,\r\n    \"RevisedAuctionQuantity\": 100,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"FinalScheduledQuantity\": 100\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionSettlementQuantities","description":"Provide the actual auction quantities and final nominations after the end of each gas day.\nThis information is required by AEMO for settlement purposes.\n\nIf multiple submissions are received by AEMO, the data received in the latest submission prior to the cut-off time is used for indicative or final settlements.\n\nAuction quantity is used for settlements if data is not received by the cut-off time"},"status":"Exceeds throttling limits OR SSL Certificate authentication validation failed","code":503,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"5afd46a8-be74-4e00-9691-5df192e09e91","name":"Response_404","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionTransactionId\": 10001,\r\n    \"RevisedAuctionQuantity\": 100,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"FinalScheduledQuantity\": 100\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionSettlementQuantities","description":"Provide the actual auction quantities and final nominations after the end of each gas day.\nThis information is required by AEMO for settlement purposes.\n\nIf multiple submissions are received by AEMO, the data received in the latest submission prior to the cut-off time is used for indicative or final settlements.\n\nAuction quantity is used for settlements if data is not received by the cut-off time"},"status":"This response is provided when the resource is missing from the URL or the URL is incorrect.","code":404,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"807ac88b-7da3-4307-b200-57ee89df4ddf","name":"Response_401","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionTransactionId\": 10001,\r\n    \"RevisedAuctionQuantity\": 100,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"FinalScheduledQuantity\": 100\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionSettlementQuantities","description":"Provide the actual auction quantities and final nominations after the end of each gas day.\nThis information is required by AEMO for settlement purposes.\n\nIf multiple submissions are received by AEMO, the data received in the latest submission prior to the cut-off time is used for indicative or final settlements.\n\nAuction quantity is used for settlements if data is not received by the cut-off time"},"status":"This response is provided when \"Authorisation\" is missing from the header OR user/password is incorrect/not provided OR user account is locked out.","code":401,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"69beb08e-727f-4c0a-94eb-fd5b4850188e","name":"Response_403","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionTransactionId\": 10001,\r\n    \"RevisedAuctionQuantity\": 100,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"FinalScheduledQuantity\": 100\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionSettlementQuantities","description":"Provide the actual auction quantities and final nominations after the end of each gas day.\nThis information is required by AEMO for settlement purposes.\n\nIf multiple submissions are received by AEMO, the data received in the latest submission prior to the cut-off time is used for indicative or final settlements.\n\nAuction quantity is used for settlements if data is not received by the cut-off time"},"status":"This response is provided when there is an invalid Role i.e. user does not have permission to submit this request.","code":403,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"42d834be-3eb4-497f-842c-d50d742db717","name":"Response_200","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionTransactionId\": 10001,\r\n    \"RevisedAuctionQuantity\": 100,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"FinalScheduledQuantity\": 100\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionSettlementQuantities","description":"Provide the actual auction quantities and final nominations after the end of each gas day.\nThis information is required by AEMO for settlement purposes.\n\nIf multiple submissions are received by AEMO, the data received in the latest submission prior to the cut-off time is used for indicative or final settlements.\n\nAuction quantity is used for settlements if data is not received by the cut-off time"},"status":"Successful reponse with Facilites report","code":200,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"826233f4-c32e-4189-8bbe-db01f3fc1fee","name":"Response_411","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionTransactionId\": 10001,\r\n    \"RevisedAuctionQuantity\": 100,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"FinalScheduledQuantity\": 100\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionSettlementQuantities","description":"Provide the actual auction quantities and final nominations after the end of each gas day.\nThis information is required by AEMO for settlement purposes.\n\nIf multiple submissions are received by AEMO, the data received in the latest submission prior to the cut-off time is used for indicative or final settlements.\n\nAuction quantity is used for settlements if data is not received by the cut-off time"},"status":"This response is provided when \"Content-Length\" is missing from the Header","code":411,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"0d21187e-43fc-4d4f-b10e-132947bf9911","name":"Response_405","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionTransactionId\": 10001,\r\n    \"RevisedAuctionQuantity\": 100,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"FinalScheduledQuantity\": 100\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionSettlementQuantities","description":"Provide the actual auction quantities and final nominations after the end of each gas day.\nThis information is required by AEMO for settlement purposes.\n\nIf multiple submissions are received by AEMO, the data received in the latest submission prior to the cut-off time is used for indicative or final settlements.\n\nAuction quantity is used for settlements if data is not received by the cut-off time"},"status":"Invalid Method used (e.g. GET used instead of POST)","code":405,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"8b0a4b93-36d3-44a5-9d67-1b6f98e86d31","name":"Response_500","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionTransactionId\": 10001,\r\n    \"RevisedAuctionQuantity\": 100,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"FinalScheduledQuantity\": 100\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionSettlementQuantities","description":"Provide the actual auction quantities and final nominations after the end of each gas day.\nThis information is required by AEMO for settlement purposes.\n\nIf multiple submissions are received by AEMO, the data received in the latest submission prior to the cut-off time is used for indicative or final settlements.\n\nAuction quantity is used for settlements if data is not received by the cut-off time"},"status":"e-Hub is operational but downstream systems are not available.","code":500,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"bfb34649-5d97-4750-822c-1a37c170f810","name":"Response_422","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionTransactionId\": 10001,\r\n    \"RevisedAuctionQuantity\": 100,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"FinalScheduledQuantity\": 100\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionSettlementQuantities","description":"Provide the actual auction quantities and final nominations after the end of each gas day.\nThis information is required by AEMO for settlement purposes.\n\nIf multiple submissions are received by AEMO, the data received in the latest submission prior to the cut-off time is used for indicative or final settlements.\n\nAuction quantity is used for settlements if data is not received by the cut-off time"},"status":"This response is provided when any there are any Business validation failures, then entire submission is rejected.","code":422,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"211791eb-bae1-4624-a2c4-d2fcea32d118","name":"Response_400","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"AuctionTransactionId\": 10001,\r\n    \"RevisedAuctionQuantity\": 100,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"FinalScheduledQuantity\": 100\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionSettlementQuantities","description":"Provide the actual auction quantities and final nominations after the end of each gas day.\nThis information is required by AEMO for settlement purposes.\n\nIf multiple submissions are received by AEMO, the data received in the latest submission prior to the cut-off time is used for indicative or final settlements.\n\nAuction quantity is used for settlements if data is not received by the cut-off time"},"status":"The service cannot be found for the endpoint reference (EPR) <URI>","code":400,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""}],"_postman_id":"42f1cff2-1ed8-4bf3-957f-a8ffba5df409"},{"name":"postAuctionServiceCurtailmentNotice","id":"a45b7848-61e3-438a-9040-42de91052f38","protocolProfileBehavior":{"disableBodyPruning":true},"request":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"<p>The ID of the Initiating Participant</p>\n"},{"key":"X-market","value":"GAS","description":"<p>The market type that the request applies.</p>\n"},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"AuctionService\": \"FORWARD_HAUL\",\r\n    \"Curtailed\": \"YES\",\r\n    \"Material\": \"YES\",\r\n    \"Description\": \"Why the curtailment has occurred\",\r\n    \"EffectiveDateTime\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionServiceCurtailmentNotice","description":"<p>Provide AEMO with notice of an auction service curtailment on an auction facility during a gas day.</p>\n","auth":{"type":"basic","basic":{"basicConfig":[]},"isInherited":true,"source":{"_postman_id":"6375289a-c484-476a-8f8e-b02a7053ecd0","id":"6375289a-c484-476a-8f8e-b02a7053ecd0","name":"capacity","type":"collection"}},"urlObject":{"path":["auctionServiceCurtailmentNotice"],"host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"query":[],"variable":[]}},"response":[{"id":"807839cc-2775-46f6-94b2-f435131d1ae6","name":"Response_422","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"AuctionService\": \"FORWARD_HAUL\",\r\n    \"Curtailed\": \"YES\",\r\n    \"Material\": \"YES\",\r\n    \"Description\": \"Why the curtailment has occurred\",\r\n    \"EffectiveDateTime\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionServiceCurtailmentNotice","description":"Provide AEMO with notice of an auction service curtailment on an auction facility during a gas day."},"status":"This response is provided when any there are any Business validation failures, then entire submission is rejected.","code":422,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"7780e698-59a4-4257-b525-c30a66581ad2","name":"Response_403","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"AuctionService\": \"FORWARD_HAUL\",\r\n    \"Curtailed\": \"YES\",\r\n    \"Material\": \"YES\",\r\n    \"Description\": \"Why the curtailment has occurred\",\r\n    \"EffectiveDateTime\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionServiceCurtailmentNotice","description":"Provide AEMO with notice of an auction service curtailment on an auction facility during a gas day."},"status":"This response is provided when there is an invalid Role i.e. user does not have permission to submit this request.","code":403,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"593ad967-b819-4dd3-8fdf-200fab3206d7","name":"Response_405","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"AuctionService\": \"FORWARD_HAUL\",\r\n    \"Curtailed\": \"YES\",\r\n    \"Material\": \"YES\",\r\n    \"Description\": \"Why the curtailment has occurred\",\r\n    \"EffectiveDateTime\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionServiceCurtailmentNotice","description":"Provide AEMO with notice of an auction service curtailment on an auction facility during a gas day."},"status":"Invalid Method used (e.g. GET used instead of POST)","code":405,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"d6a9dbf5-fa8e-48d9-b0f7-cfb8c1c564eb","name":"Response_404","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"AuctionService\": \"FORWARD_HAUL\",\r\n    \"Curtailed\": \"YES\",\r\n    \"Material\": \"YES\",\r\n    \"Description\": \"Why the curtailment has occurred\",\r\n    \"EffectiveDateTime\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionServiceCurtailmentNotice","description":"Provide AEMO with notice of an auction service curtailment on an auction facility during a gas day."},"status":"This response is provided when the resource is missing from the URL or the URL is incorrect.","code":404,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"651a0395-42ce-4685-b9ee-e46d35b02f40","name":"Response_411","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"AuctionService\": \"FORWARD_HAUL\",\r\n    \"Curtailed\": \"YES\",\r\n    \"Material\": \"YES\",\r\n    \"Description\": \"Why the curtailment has occurred\",\r\n    \"EffectiveDateTime\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionServiceCurtailmentNotice","description":"Provide AEMO with notice of an auction service curtailment on an auction facility during a gas day."},"status":"This response is provided when \"Content-Length\" is missing from the Header","code":411,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"636d1862-75e4-4796-ac1f-656c5f26469d","name":"Response_200","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"AuctionService\": \"FORWARD_HAUL\",\r\n    \"Curtailed\": \"YES\",\r\n    \"Material\": \"YES\",\r\n    \"Description\": \"Why the curtailment has occurred\",\r\n    \"EffectiveDateTime\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionServiceCurtailmentNotice","description":"Provide AEMO with notice of an auction service curtailment on an auction facility during a gas day."},"status":"Successful","code":200,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"be4a3603-4b24-434f-89a0-f6815ca9e6be","name":"Response_500","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"AuctionService\": \"FORWARD_HAUL\",\r\n    \"Curtailed\": \"YES\",\r\n    \"Material\": \"YES\",\r\n    \"Description\": \"Why the curtailment has occurred\",\r\n    \"EffectiveDateTime\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionServiceCurtailmentNotice","description":"Provide AEMO with notice of an auction service curtailment on an auction facility during a gas day."},"status":"e-Hub is operational but downstream systems are not available.","code":500,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"658f070d-11c9-4b54-ba73-ab262f18fbb9","name":"Response_400","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"AuctionService\": \"FORWARD_HAUL\",\r\n    \"Curtailed\": \"YES\",\r\n    \"Material\": \"YES\",\r\n    \"Description\": \"Why the curtailment has occurred\",\r\n    \"EffectiveDateTime\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionServiceCurtailmentNotice","description":"Provide AEMO with notice of an auction service curtailment on an auction facility during a gas day."},"status":"The service cannot be found for the endpoint reference (EPR) <URI>","code":400,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"6769e6b8-0210-4389-8e88-72d3ecea1323","name":"Response_401","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"AuctionService\": \"FORWARD_HAUL\",\r\n    \"Curtailed\": \"YES\",\r\n    \"Material\": \"YES\",\r\n    \"Description\": \"Why the curtailment has occurred\",\r\n    \"EffectiveDateTime\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionServiceCurtailmentNotice","description":"Provide AEMO with notice of an auction service curtailment on an auction facility during a gas day."},"status":"This response is provided when \"Authorisation\" is missing from the header OR user/password is incorrect/not provided OR user account is locked out.","code":401,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"3ad6c1c9-6ce2-4390-adc1-ab8e58d7cf82","name":"Response_503","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"AuctionService\": \"FORWARD_HAUL\",\r\n    \"Curtailed\": \"YES\",\r\n    \"Material\": \"YES\",\r\n    \"Description\": \"Why the curtailment has occurred\",\r\n    \"EffectiveDateTime\": \"2018-05-01T00:00:00\",\r\n    \"GasDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/auctionServiceCurtailmentNotice","description":"Provide AEMO with notice of an auction service curtailment on an auction facility during a gas day."},"status":"Exceeds throttling limits OR SSL Certificate authentication validation failed","code":503,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""}],"_postman_id":"a45b7848-61e3-438a-9040-42de91052f38"},{"name":"postZoneCurtailmentInformation","id":"89defe43-161a-40ed-b547-52fc34bceb3b","protocolProfileBehavior":{"disableBodyPruning":true},"request":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"<p>The ID of the Initiating Participant</p>\n"},{"key":"X-market","value":"GAS","description":"<p>The market type that the request applies.</p>\n"},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ServicePointId\": 3001,\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"CurtailedQuantity\": 455\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/zoneCurtailmentInformation","description":"<p>Provide AEMO with notice of curtailed shipper nominations against secondary firm rights.</p>\n","auth":{"type":"basic","basic":{"basicConfig":[]},"isInherited":true,"source":{"_postman_id":"6375289a-c484-476a-8f8e-b02a7053ecd0","id":"6375289a-c484-476a-8f8e-b02a7053ecd0","name":"capacity","type":"collection"}},"urlObject":{"path":["zoneCurtailmentInformation"],"host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"query":[],"variable":[]}},"response":[{"id":"c757c849-0ecb-4c9a-894c-2bd2f722fa2b","name":"Response_500","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ServicePointId\": 3001,\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"CurtailedQuantity\": 455\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/zoneCurtailmentInformation","description":"Provide AEMO with notice of curtailed shipper nominations against secondary firm rights."},"status":"e-Hub is operational but downstream systems are not available.","code":500,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"a62dadfd-c583-4070-bee9-67d03b0c1a32","name":"Response_503","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ServicePointId\": 3001,\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"CurtailedQuantity\": 455\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/zoneCurtailmentInformation","description":"Provide AEMO with notice of curtailed shipper nominations against secondary firm rights."},"status":"Exceeds throttling limits OR SSL Certificate authentication validation failed","code":503,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"4e74d665-f128-47b5-97df-6e8940382223","name":"Response_403","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ServicePointId\": 3001,\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"CurtailedQuantity\": 455\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/zoneCurtailmentInformation","description":"Provide AEMO with notice of curtailed shipper nominations against secondary firm rights."},"status":"This response is provided when there is an invalid Role i.e. user does not have permission to submit this request.","code":403,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"1852787f-1800-4f51-949c-4de1b4813745","name":"Response_411","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ServicePointId\": 3001,\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"CurtailedQuantity\": 455\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/zoneCurtailmentInformation","description":"Provide AEMO with notice of curtailed shipper nominations against secondary firm rights."},"status":"This response is provided when \"Content-Length\" is missing from the Header","code":411,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"6cce3c14-0299-4a06-8923-db6d51fdbbb2","name":"Response_400","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ServicePointId\": 3001,\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"CurtailedQuantity\": 455\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/zoneCurtailmentInformation","description":"Provide AEMO with notice of curtailed shipper nominations against secondary firm rights."},"status":"The service cannot be found for the endpoint reference (EPR) <URI>","code":400,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"b4c0ff8b-698e-42c0-a948-7c9589679587","name":"Response_404","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ServicePointId\": 3001,\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"CurtailedQuantity\": 455\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/zoneCurtailmentInformation","description":"Provide AEMO with notice of curtailed shipper nominations against secondary firm rights."},"status":"This response is provided when the resource is missing from the URL or the URL is incorrect.","code":404,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"5217f2c9-ad82-40c1-9b9d-28b6f4018229","name":"Response_200","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ServicePointId\": 3001,\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"CurtailedQuantity\": 455\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/zoneCurtailmentInformation","description":"Provide AEMO with notice of curtailed shipper nominations against secondary firm rights."},"status":"Successful","code":200,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"259173d3-c093-4d3c-94af-e9de84d2a4ad","name":"Response_405","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ServicePointId\": 3001,\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"CurtailedQuantity\": 455\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/zoneCurtailmentInformation","description":"Provide AEMO with notice of curtailed shipper nominations against secondary firm rights."},"status":"Invalid Method used (e.g. GET used instead of POST)","code":405,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"fc54fd72-591d-4693-88aa-b0f0b89cefc3","name":"Response_401","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ServicePointId\": 3001,\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"CurtailedQuantity\": 455\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/zoneCurtailmentInformation","description":"Provide AEMO with notice of curtailed shipper nominations against secondary firm rights."},"status":"This response is provided when \"Authorisation\" is missing from the header OR user/password is incorrect/not provided OR user account is locked out.","code":401,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"853ee7ad-72a1-40df-ac3c-b042344edd88","name":"Response_422","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ServicePointId\": 3001,\r\n    \"GasDate\": \"2018-05-01T00:00:00\",\r\n    \"CurtailedQuantity\": 455\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/zoneCurtailmentInformation","description":"Provide AEMO with notice of curtailed shipper nominations against secondary firm rights."},"status":"This response is provided when any there are any Business validation failures, then entire submission is rejected.","code":422,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""}],"_postman_id":"89defe43-161a-40ed-b547-52fc34bceb3b"},{"name":"postCapacityTransferStatus","id":"98250f30-903b-4660-968c-221d9e583bd3","protocolProfileBehavior":{"disableBodyPruning":true},"request":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"<p>The ID of the Initiating Participant</p>\n"},{"key":"X-market","value":"GAS","description":"<p>The market type that the request applies.</p>\n"},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"CapacityTransferId\": 10001,\r\n    \"TransactionStatus\": \"TRANSFERRED\",\r\n    \"ConfirmedCapacityQuantity\": 96,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"InvalidQuantity\": 30\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/capacityTransferStatus","description":"<p>Provide a status of capacity transfer for each capacity transfer notice.</p>\n<p>Partial submissions are accepted. This allows facility operators to submit interim PENDING statuses for transfers that have failed.</p>\n<p>Facility operators are responsible for pro-rating capacity quantities where applicable i.e. if there is a shipper capacity shortfall.</p>\n<p>Facility operators may continue to submit this transaction beyond the cut-off time for the purposes of updating the invalid quantity and reason.</p>\n<p>Changes to day ahead capacity transfer transaction status and confirmed capacity quantity will be ignored after the day ahead transfer cut-off time.</p>\n<p>Changes to D-2 and ‘bundled products’ forward traded capacity transfer transaction status and confirmed capacity quantity will be ignored after the forward traded capacity transfer cut-off time.</p>\n<p>Changes to D-3 (and beyond) forward traded capacity transaction status and confirmed capacity quantity will be accepted for up to 24 hours after the forward traded capacity transfer cut-off time.</p>\n","auth":{"type":"basic","basic":{"basicConfig":[]},"isInherited":true,"source":{"_postman_id":"6375289a-c484-476a-8f8e-b02a7053ecd0","id":"6375289a-c484-476a-8f8e-b02a7053ecd0","name":"capacity","type":"collection"}},"urlObject":{"path":["capacityTransferStatus"],"host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"query":[],"variable":[]}},"response":[{"id":"7ebdefbc-ab6d-416d-b096-f85ef7803274","name":"Response_422","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"CapacityTransferId\": 10001,\r\n    \"TransactionStatus\": \"TRANSFERRED\",\r\n    \"ConfirmedCapacityQuantity\": 96,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"InvalidQuantity\": 30\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/capacityTransferStatus","description":"Provide a status of capacity transfer for each capacity transfer notice.\n\nPartial submissions are accepted. This allows facility operators to submit interim PENDING statuses for transfers that have failed.\n\nFacility operators are responsible for pro-rating capacity quantities where applicable i.e. if there is a shipper capacity shortfall.\n\nFacility operators may continue to submit this transaction beyond the cut-off time for the purposes of updating the invalid quantity and reason.\n\nChanges to day ahead capacity transfer transaction status and confirmed capacity quantity will be ignored after the day ahead transfer cut-off time.\n\nChanges to D-2 and ‘bundled products’ forward traded capacity transfer transaction status and confirmed capacity quantity will be ignored after the forward traded capacity transfer cut-off time.\n\nChanges to D-3 (and beyond) forward traded capacity transaction status and confirmed capacity quantity will be accepted for up to 24 hours after the forward traded capacity transfer cut-off time."},"status":"This response is provided when any there are any Business validation failures, then entire submission is rejected.","code":422,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"2bfc331e-a2a0-4491-9e53-c462948f19a4","name":"Response_503","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"CapacityTransferId\": 10001,\r\n    \"TransactionStatus\": \"TRANSFERRED\",\r\n    \"ConfirmedCapacityQuantity\": 96,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"InvalidQuantity\": 30\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/capacityTransferStatus","description":"Provide a status of capacity transfer for each capacity transfer notice.\n\nPartial submissions are accepted. This allows facility operators to submit interim PENDING statuses for transfers that have failed.\n\nFacility operators are responsible for pro-rating capacity quantities where applicable i.e. if there is a shipper capacity shortfall.\n\nFacility operators may continue to submit this transaction beyond the cut-off time for the purposes of updating the invalid quantity and reason.\n\nChanges to day ahead capacity transfer transaction status and confirmed capacity quantity will be ignored after the day ahead transfer cut-off time.\n\nChanges to D-2 and ‘bundled products’ forward traded capacity transfer transaction status and confirmed capacity quantity will be ignored after the forward traded capacity transfer cut-off time.\n\nChanges to D-3 (and beyond) forward traded capacity transaction status and confirmed capacity quantity will be accepted for up to 24 hours after the forward traded capacity transfer cut-off time."},"status":"Exceeds throttling limits OR SSL Certificate authentication validation failed","code":503,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"cadd352f-9b53-4ee4-bd9d-f93ed8578a82","name":"Response_405","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"CapacityTransferId\": 10001,\r\n    \"TransactionStatus\": \"TRANSFERRED\",\r\n    \"ConfirmedCapacityQuantity\": 96,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"InvalidQuantity\": 30\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/capacityTransferStatus","description":"Provide a status of capacity transfer for each capacity transfer notice.\n\nPartial submissions are accepted. This allows facility operators to submit interim PENDING statuses for transfers that have failed.\n\nFacility operators are responsible for pro-rating capacity quantities where applicable i.e. if there is a shipper capacity shortfall.\n\nFacility operators may continue to submit this transaction beyond the cut-off time for the purposes of updating the invalid quantity and reason.\n\nChanges to day ahead capacity transfer transaction status and confirmed capacity quantity will be ignored after the day ahead transfer cut-off time.\n\nChanges to D-2 and ‘bundled products’ forward traded capacity transfer transaction status and confirmed capacity quantity will be ignored after the forward traded capacity transfer cut-off time.\n\nChanges to D-3 (and beyond) forward traded capacity transaction status and confirmed capacity quantity will be accepted for up to 24 hours after the forward traded capacity transfer cut-off time."},"status":"Invalid Method used (e.g. GET used instead of POST)","code":405,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"34b09c24-fb01-44ae-abe1-69b7c817ea27","name":"Response_404","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"CapacityTransferId\": 10001,\r\n    \"TransactionStatus\": \"TRANSFERRED\",\r\n    \"ConfirmedCapacityQuantity\": 96,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"InvalidQuantity\": 30\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/capacityTransferStatus","description":"Provide a status of capacity transfer for each capacity transfer notice.\n\nPartial submissions are accepted. This allows facility operators to submit interim PENDING statuses for transfers that have failed.\n\nFacility operators are responsible for pro-rating capacity quantities where applicable i.e. if there is a shipper capacity shortfall.\n\nFacility operators may continue to submit this transaction beyond the cut-off time for the purposes of updating the invalid quantity and reason.\n\nChanges to day ahead capacity transfer transaction status and confirmed capacity quantity will be ignored after the day ahead transfer cut-off time.\n\nChanges to D-2 and ‘bundled products’ forward traded capacity transfer transaction status and confirmed capacity quantity will be ignored after the forward traded capacity transfer cut-off time.\n\nChanges to D-3 (and beyond) forward traded capacity transaction status and confirmed capacity quantity will be accepted for up to 24 hours after the forward traded capacity transfer cut-off time."},"status":"This response is provided when the resource is missing from the URL or the URL is incorrect.","code":404,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"861a8aa9-1d88-41c2-8fb1-4be0a9ec71f4","name":"Response_200","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"CapacityTransferId\": 10001,\r\n    \"TransactionStatus\": \"TRANSFERRED\",\r\n    \"ConfirmedCapacityQuantity\": 96,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"InvalidQuantity\": 30\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/capacityTransferStatus","description":"Provide a status of capacity transfer for each capacity transfer notice.\n\nPartial submissions are accepted. This allows facility operators to submit interim PENDING statuses for transfers that have failed.\n\nFacility operators are responsible for pro-rating capacity quantities where applicable i.e. if there is a shipper capacity shortfall.\n\nFacility operators may continue to submit this transaction beyond the cut-off time for the purposes of updating the invalid quantity and reason.\n\nChanges to day ahead capacity transfer transaction status and confirmed capacity quantity will be ignored after the day ahead transfer cut-off time.\n\nChanges to D-2 and ‘bundled products’ forward traded capacity transfer transaction status and confirmed capacity quantity will be ignored after the forward traded capacity transfer cut-off time.\n\nChanges to D-3 (and beyond) forward traded capacity transaction status and confirmed capacity quantity will be accepted for up to 24 hours after the forward traded capacity transfer cut-off time."},"status":"Successful","code":200,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"bd6f6899-3efd-4969-862b-dec29cba62f4","name":"Response_400","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"CapacityTransferId\": 10001,\r\n    \"TransactionStatus\": \"TRANSFERRED\",\r\n    \"ConfirmedCapacityQuantity\": 96,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"InvalidQuantity\": 30\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/capacityTransferStatus","description":"Provide a status of capacity transfer for each capacity transfer notice.\n\nPartial submissions are accepted. This allows facility operators to submit interim PENDING statuses for transfers that have failed.\n\nFacility operators are responsible for pro-rating capacity quantities where applicable i.e. if there is a shipper capacity shortfall.\n\nFacility operators may continue to submit this transaction beyond the cut-off time for the purposes of updating the invalid quantity and reason.\n\nChanges to day ahead capacity transfer transaction status and confirmed capacity quantity will be ignored after the day ahead transfer cut-off time.\n\nChanges to D-2 and ‘bundled products’ forward traded capacity transfer transaction status and confirmed capacity quantity will be ignored after the forward traded capacity transfer cut-off time.\n\nChanges to D-3 (and beyond) forward traded capacity transaction status and confirmed capacity quantity will be accepted for up to 24 hours after the forward traded capacity transfer cut-off time."},"status":"The service cannot be found for the endpoint reference (EPR) <URI>","code":400,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"61e8025b-a08e-4e2a-a894-3cca39d1dfaa","name":"Response_411","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"CapacityTransferId\": 10001,\r\n    \"TransactionStatus\": \"TRANSFERRED\",\r\n    \"ConfirmedCapacityQuantity\": 96,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"InvalidQuantity\": 30\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/capacityTransferStatus","description":"Provide a status of capacity transfer for each capacity transfer notice.\n\nPartial submissions are accepted. This allows facility operators to submit interim PENDING statuses for transfers that have failed.\n\nFacility operators are responsible for pro-rating capacity quantities where applicable i.e. if there is a shipper capacity shortfall.\n\nFacility operators may continue to submit this transaction beyond the cut-off time for the purposes of updating the invalid quantity and reason.\n\nChanges to day ahead capacity transfer transaction status and confirmed capacity quantity will be ignored after the day ahead transfer cut-off time.\n\nChanges to D-2 and ‘bundled products’ forward traded capacity transfer transaction status and confirmed capacity quantity will be ignored after the forward traded capacity transfer cut-off time.\n\nChanges to D-3 (and beyond) forward traded capacity transaction status and confirmed capacity quantity will be accepted for up to 24 hours after the forward traded capacity transfer cut-off time."},"status":"This response is provided when \"Content-Length\" is missing from the Header","code":411,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"513fa4a8-49c9-4419-815f-900db1ed5f29","name":"Response_401","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"CapacityTransferId\": 10001,\r\n    \"TransactionStatus\": \"TRANSFERRED\",\r\n    \"ConfirmedCapacityQuantity\": 96,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"InvalidQuantity\": 30\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/capacityTransferStatus","description":"Provide a status of capacity transfer for each capacity transfer notice.\n\nPartial submissions are accepted. This allows facility operators to submit interim PENDING statuses for transfers that have failed.\n\nFacility operators are responsible for pro-rating capacity quantities where applicable i.e. if there is a shipper capacity shortfall.\n\nFacility operators may continue to submit this transaction beyond the cut-off time for the purposes of updating the invalid quantity and reason.\n\nChanges to day ahead capacity transfer transaction status and confirmed capacity quantity will be ignored after the day ahead transfer cut-off time.\n\nChanges to D-2 and ‘bundled products’ forward traded capacity transfer transaction status and confirmed capacity quantity will be ignored after the forward traded capacity transfer cut-off time.\n\nChanges to D-3 (and beyond) forward traded capacity transaction status and confirmed capacity quantity will be accepted for up to 24 hours after the forward traded capacity transfer cut-off time."},"status":"This response is provided when \"Authorisation\" is missing from the header OR user/password is incorrect/not provided OR user account is locked out.","code":401,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"9857eca1-95ce-4b92-8ff7-5930f3de0163","name":"Response_500","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"CapacityTransferId\": 10001,\r\n    \"TransactionStatus\": \"TRANSFERRED\",\r\n    \"ConfirmedCapacityQuantity\": 96,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"InvalidQuantity\": 30\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/capacityTransferStatus","description":"Provide a status of capacity transfer for each capacity transfer notice.\n\nPartial submissions are accepted. This allows facility operators to submit interim PENDING statuses for transfers that have failed.\n\nFacility operators are responsible for pro-rating capacity quantities where applicable i.e. if there is a shipper capacity shortfall.\n\nFacility operators may continue to submit this transaction beyond the cut-off time for the purposes of updating the invalid quantity and reason.\n\nChanges to day ahead capacity transfer transaction status and confirmed capacity quantity will be ignored after the day ahead transfer cut-off time.\n\nChanges to D-2 and ‘bundled products’ forward traded capacity transfer transaction status and confirmed capacity quantity will be ignored after the forward traded capacity transfer cut-off time.\n\nChanges to D-3 (and beyond) forward traded capacity transaction status and confirmed capacity quantity will be accepted for up to 24 hours after the forward traded capacity transfer cut-off time."},"status":"e-Hub is operational but downstream systems are not available.","code":500,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"70174c02-8d9a-4329-b79f-166a9950f550","name":"Response_403","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"CapacityTransferId\": 10001,\r\n    \"TransactionStatus\": \"TRANSFERRED\",\r\n    \"ConfirmedCapacityQuantity\": 96,\r\n    \"Reason\": \"PIPELINE_CONSTRAINED\",\r\n    \"InvalidQuantity\": 30\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/capacityTransferStatus","description":"Provide a status of capacity transfer for each capacity transfer notice.\n\nPartial submissions are accepted. This allows facility operators to submit interim PENDING statuses for transfers that have failed.\n\nFacility operators are responsible for pro-rating capacity quantities where applicable i.e. if there is a shipper capacity shortfall.\n\nFacility operators may continue to submit this transaction beyond the cut-off time for the purposes of updating the invalid quantity and reason.\n\nChanges to day ahead capacity transfer transaction status and confirmed capacity quantity will be ignored after the day ahead transfer cut-off time.\n\nChanges to D-2 and ‘bundled products’ forward traded capacity transfer transaction status and confirmed capacity quantity will be ignored after the forward traded capacity transfer cut-off time.\n\nChanges to D-3 (and beyond) forward traded capacity transaction status and confirmed capacity quantity will be accepted for up to 24 hours after the forward traded capacity transfer cut-off time."},"status":"This response is provided when there is an invalid Role i.e. user does not have permission to submit this request.","code":403,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""}],"_postman_id":"98250f30-903b-4660-968c-221d9e583bd3"},{"name":"postContractDetails","id":"d4c27952-e02d-4d34-94be-6ea3b1f7fc2a","protocolProfileBehavior":{"disableBodyPruning":true},"request":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"<p>The ID of the Initiating Participant</p>\n"},{"key":"X-market","value":"GAS","description":"<p>The market type that the request applies.</p>\n"},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ParticipantId\": \"13\",\r\n    \"ServiceReference\": \"SR00000001\",\r\n    \"ServiceReferenceDescription\": \"ID for service in easterly direction\",\r\n    \"STTMContractReference\": \"RS0000011\",\r\n    \"ContractType\": \"TRADE\",\r\n    \"StartDate\": \"2018-05-01T00:00:00\",\r\n    \"EndDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/contractDetails","description":"<p>Each submission must contain the full set of shipper contracts that are valid beyond the submission date in accordance with the Procedures.\nOn submission of this data, the system replaces all contract details previously submitted by the facility operator with the contents of the new submission.\nThis information is used by shippers to select an appropriate contract for a capacity product prior to trading.\nSTTM contract references must be firm i.e. must be a Priority 1 registered facility service.</p>\n","auth":{"type":"basic","basic":{"basicConfig":[]},"isInherited":true,"source":{"_postman_id":"6375289a-c484-476a-8f8e-b02a7053ecd0","id":"6375289a-c484-476a-8f8e-b02a7053ecd0","name":"capacity","type":"collection"}},"urlObject":{"path":["contractDetails"],"host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"query":[],"variable":[]}},"response":[{"id":"5d559d4c-00bc-4305-8e59-17d582b1a82b","name":"Response_411","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ParticipantId\": \"13\",\r\n    \"ServiceReference\": \"SR00000001\",\r\n    \"ServiceReferenceDescription\": \"ID for service in easterly direction\",\r\n    \"STTMContractReference\": \"RS0000011\",\r\n    \"ContractType\": \"TRADE\",\r\n    \"StartDate\": \"2018-05-01T00:00:00\",\r\n    \"EndDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/contractDetails","description":"Each submission must contain the full set of shipper contracts that are valid beyond the submission date in accordance with the Procedures.\nOn submission of this data, the system replaces all contract details previously submitted by the facility operator with the contents of the new submission.\nThis information is used by shippers to select an appropriate contract for a capacity product prior to trading.\nSTTM contract references must be firm i.e. must be a Priority 1 registered facility service."},"status":"This response is provided when \"Content-Length\" is missing from the Header","code":411,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"b524771f-467f-4b97-ad62-dd0e5da6c70a","name":"Response_422","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ParticipantId\": \"13\",\r\n    \"ServiceReference\": \"SR00000001\",\r\n    \"ServiceReferenceDescription\": \"ID for service in easterly direction\",\r\n    \"STTMContractReference\": \"RS0000011\",\r\n    \"ContractType\": \"TRADE\",\r\n    \"StartDate\": \"2018-05-01T00:00:00\",\r\n    \"EndDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/contractDetails","description":"Each submission must contain the full set of shipper contracts that are valid beyond the submission date in accordance with the Procedures.\nOn submission of this data, the system replaces all contract details previously submitted by the facility operator with the contents of the new submission.\nThis information is used by shippers to select an appropriate contract for a capacity product prior to trading.\nSTTM contract references must be firm i.e. must be a Priority 1 registered facility service."},"status":"This response is provided when any there are any Business validation failures, then entire submission is rejected.","code":422,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"92f5e8f7-7bf8-4a82-a5e9-8dc75173250e","name":"Response_401","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ParticipantId\": \"13\",\r\n    \"ServiceReference\": \"SR00000001\",\r\n    \"ServiceReferenceDescription\": \"ID for service in easterly direction\",\r\n    \"STTMContractReference\": \"RS0000011\",\r\n    \"ContractType\": \"TRADE\",\r\n    \"StartDate\": \"2018-05-01T00:00:00\",\r\n    \"EndDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/contractDetails","description":"Each submission must contain the full set of shipper contracts that are valid beyond the submission date in accordance with the Procedures.\nOn submission of this data, the system replaces all contract details previously submitted by the facility operator with the contents of the new submission.\nThis information is used by shippers to select an appropriate contract for a capacity product prior to trading.\nSTTM contract references must be firm i.e. must be a Priority 1 registered facility service."},"status":"This response is provided when \"Authorisation\" is missing from the header OR user/password is incorrect/not provided OR user account is locked out.","code":401,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"6eb7f367-d20e-4ea9-a132-77600cb40af1","name":"Response_404","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ParticipantId\": \"13\",\r\n    \"ServiceReference\": \"SR00000001\",\r\n    \"ServiceReferenceDescription\": \"ID for service in easterly direction\",\r\n    \"STTMContractReference\": \"RS0000011\",\r\n    \"ContractType\": \"TRADE\",\r\n    \"StartDate\": \"2018-05-01T00:00:00\",\r\n    \"EndDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/contractDetails","description":"Each submission must contain the full set of shipper contracts that are valid beyond the submission date in accordance with the Procedures.\nOn submission of this data, the system replaces all contract details previously submitted by the facility operator with the contents of the new submission.\nThis information is used by shippers to select an appropriate contract for a capacity product prior to trading.\nSTTM contract references must be firm i.e. must be a Priority 1 registered facility service."},"status":"This response is provided when the resource is missing from the URL or the URL is incorrect.","code":404,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"be7076ef-0253-42da-b7f3-e65c3df4cee7","name":"Response_200","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ParticipantId\": \"13\",\r\n    \"ServiceReference\": \"SR00000001\",\r\n    \"ServiceReferenceDescription\": \"ID for service in easterly direction\",\r\n    \"STTMContractReference\": \"RS0000011\",\r\n    \"ContractType\": \"TRADE\",\r\n    \"StartDate\": \"2018-05-01T00:00:00\",\r\n    \"EndDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/contractDetails","description":"Each submission must contain the full set of shipper contracts that are valid beyond the submission date in accordance with the Procedures.\nOn submission of this data, the system replaces all contract details previously submitted by the facility operator with the contents of the new submission.\nThis information is used by shippers to select an appropriate contract for a capacity product prior to trading.\nSTTM contract references must be firm i.e. must be a Priority 1 registered facility service."},"status":"Successful","code":200,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"284e5223-60c3-4bd0-b169-f9390c6ea8c7","name":"Response_503","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ParticipantId\": \"13\",\r\n    \"ServiceReference\": \"SR00000001\",\r\n    \"ServiceReferenceDescription\": \"ID for service in easterly direction\",\r\n    \"STTMContractReference\": \"RS0000011\",\r\n    \"ContractType\": \"TRADE\",\r\n    \"StartDate\": \"2018-05-01T00:00:00\",\r\n    \"EndDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/contractDetails","description":"Each submission must contain the full set of shipper contracts that are valid beyond the submission date in accordance with the Procedures.\nOn submission of this data, the system replaces all contract details previously submitted by the facility operator with the contents of the new submission.\nThis information is used by shippers to select an appropriate contract for a capacity product prior to trading.\nSTTM contract references must be firm i.e. must be a Priority 1 registered facility service."},"status":"Exceeds throttling limits OR SSL Certificate authentication validation failed","code":503,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"ff265059-119c-4eeb-b717-c5cd8cea87a3","name":"Response_403","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ParticipantId\": \"13\",\r\n    \"ServiceReference\": \"SR00000001\",\r\n    \"ServiceReferenceDescription\": \"ID for service in easterly direction\",\r\n    \"STTMContractReference\": \"RS0000011\",\r\n    \"ContractType\": \"TRADE\",\r\n    \"StartDate\": \"2018-05-01T00:00:00\",\r\n    \"EndDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/contractDetails","description":"Each submission must contain the full set of shipper contracts that are valid beyond the submission date in accordance with the Procedures.\nOn submission of this data, the system replaces all contract details previously submitted by the facility operator with the contents of the new submission.\nThis information is used by shippers to select an appropriate contract for a capacity product prior to trading.\nSTTM contract references must be firm i.e. must be a Priority 1 registered facility service."},"status":"This response is provided when there is an invalid Role i.e. user does not have permission to submit this request.","code":403,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"91a85499-55a3-4457-ab1c-09248cee185c","name":"Response_400","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ParticipantId\": \"13\",\r\n    \"ServiceReference\": \"SR00000001\",\r\n    \"ServiceReferenceDescription\": \"ID for service in easterly direction\",\r\n    \"STTMContractReference\": \"RS0000011\",\r\n    \"ContractType\": \"TRADE\",\r\n    \"StartDate\": \"2018-05-01T00:00:00\",\r\n    \"EndDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/contractDetails","description":"Each submission must contain the full set of shipper contracts that are valid beyond the submission date in accordance with the Procedures.\nOn submission of this data, the system replaces all contract details previously submitted by the facility operator with the contents of the new submission.\nThis information is used by shippers to select an appropriate contract for a capacity product prior to trading.\nSTTM contract references must be firm i.e. must be a Priority 1 registered facility service."},"status":"The service cannot be found for the endpoint reference (EPR) <URI>","code":400,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"677c9dfb-3225-4491-980d-0726466e0203","name":"Response_500","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ParticipantId\": \"13\",\r\n    \"ServiceReference\": \"SR00000001\",\r\n    \"ServiceReferenceDescription\": \"ID for service in easterly direction\",\r\n    \"STTMContractReference\": \"RS0000011\",\r\n    \"ContractType\": \"TRADE\",\r\n    \"StartDate\": \"2018-05-01T00:00:00\",\r\n    \"EndDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/contractDetails","description":"Each submission must contain the full set of shipper contracts that are valid beyond the submission date in accordance with the Procedures.\nOn submission of this data, the system replaces all contract details previously submitted by the facility operator with the contents of the new submission.\nThis information is used by shippers to select an appropriate contract for a capacity product prior to trading.\nSTTM contract references must be firm i.e. must be a Priority 1 registered facility service."},"status":"e-Hub is operational but downstream systems are not available.","code":500,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"65105cc0-00ce-42cc-b1ac-1f728b25d305","name":"Response_405","originalRequest":{"method":"POST","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"*/*"},{"key":"Content-Type","value":"application/json"}],"body":{"mode":"raw","raw":"{\r\n  \"ItemList\": {\r\n    \"FacilityId\": 530001,\r\n    \"ParticipantId\": \"13\",\r\n    \"ServiceReference\": \"SR00000001\",\r\n    \"ServiceReferenceDescription\": \"ID for service in easterly direction\",\r\n    \"STTMContractReference\": \"RS0000011\",\r\n    \"ContractType\": \"TRADE\",\r\n    \"StartDate\": \"2018-05-01T00:00:00\",\r\n    \"EndDate\": \"2018-05-01T00:00:00\"\r\n  }\r\n}"},"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/contractDetails","description":"Each submission must contain the full set of shipper contracts that are valid beyond the submission date in accordance with the Procedures.\nOn submission of this data, the system replaces all contract details previously submitted by the facility operator with the contents of the new submission.\nThis information is used by shippers to select an appropriate contract for a capacity product prior to trading.\nSTTM contract references must be firm i.e. must be a Priority 1 registered facility service."},"status":"Invalid Method used (e.g. GET used instead of POST)","code":405,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""}],"_postman_id":"d4c27952-e02d-4d34-94be-6ea3b1f7fc2a"},{"name":"getReportAuctionResults","id":"eb818fbf-5110-4ae2-8a6f-c7197dd98b07","protocolProfileBehavior":{"disableBodyPruning":true},"request":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"<p>The ID of the Initiating Participant</p>\n"},{"key":"X-market","value":"GAS","description":"<p>The market type that the request applies.</p>\n"},{"key":"Accept","value":"application/json"}],"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportAuctionResults?FacilityId=530001&FromAuctionDate=2018-02-23&ToAuctionDate=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","description":"<p>Provide the capacity quantity won by shippers at auction.</p>\n<p>Facility operators use this data to assign capacity of auction services to shippers.</p>\n<p>Facility operators that have an active facility in the auction will receive this report, regardless of whether there is any auction quantity won on their facility.</p>\n<p>Auction participants that have an active bid in the auction will receive this report, regardless of whether they win any capacity in the auction.</p>\n","auth":{"type":"basic","basic":{"basicConfig":[]},"isInherited":true,"source":{"_postman_id":"6375289a-c484-476a-8f8e-b02a7053ecd0","id":"6375289a-c484-476a-8f8e-b02a7053ecd0","name":"capacity","type":"collection"}},"urlObject":{"path":["reportAuctionResults"],"host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"query":[{"description":{"content":"<p>The unique AEMO defined Facility identifier.</p>\n","type":"text/plain"},"key":"FacilityId","value":"530001"},{"description":{"content":"<p>From Auction Date</p>\n","type":"text/plain"},"key":"FromAuctionDate","value":"2018-02-23"},{"description":{"content":"<p>To Auction Date</p>\n","type":"text/plain"},"key":"ToAuctionDate","value":"2018-02-23"},{"description":{"content":"<p>One calendar month from request date</p>\n","type":"text/plain"},"key":"FromGasDate","value":"2018-07-01"},{"description":{"content":"<p>Request date</p>\n","type":"text/plain"},"key":"ToGasDate","value":"2018-07-01"}],"variable":[]}},"response":[{"id":"2a8344a1-62b9-4c1f-bc55-854051c89ab5","name":"Response_411","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportAuctionResults?FacilityId=530001&FromAuctionDate=2018-02-23&ToAuctionDate=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportAuctionResults"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"FromAuctionDate","value":"2018-02-23","description":"From Auction Date"},{"key":"ToAuctionDate","value":"2018-02-23","description":"To Auction Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity won by shippers at auction.\n\nFacility operators use this data to assign capacity of auction services to shippers.\n\nFacility operators that have an active facility in the auction will receive this report, regardless of whether there is any auction quantity won on their facility.\n\nAuction participants that have an active bid in the auction will receive this report, regardless of whether they win any capacity in the auction."},"status":"This response is provided when \"Content-Length\" is missing from the Header","code":411,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"f63513e8-5d81-4c22-aa63-89b6695c73f6","name":"Response_403","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportAuctionResults?FacilityId=530001&FromAuctionDate=2018-02-23&ToAuctionDate=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportAuctionResults"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"FromAuctionDate","value":"2018-02-23","description":"From Auction Date"},{"key":"ToAuctionDate","value":"2018-02-23","description":"To Auction Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity won by shippers at auction.\n\nFacility operators use this data to assign capacity of auction services to shippers.\n\nFacility operators that have an active facility in the auction will receive this report, regardless of whether there is any auction quantity won on their facility.\n\nAuction participants that have an active bid in the auction will receive this report, regardless of whether they win any capacity in the auction."},"status":"This response is provided when there is an invalid Role i.e. user does not have permission to submit this request.","code":403,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"02a24c26-637f-4302-9ad0-9d812e0dcc7a","name":"Response_401","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportAuctionResults?FacilityId=530001&FromAuctionDate=2018-02-23&ToAuctionDate=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportAuctionResults"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"FromAuctionDate","value":"2018-02-23","description":"From Auction Date"},{"key":"ToAuctionDate","value":"2018-02-23","description":"To Auction Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity won by shippers at auction.\n\nFacility operators use this data to assign capacity of auction services to shippers.\n\nFacility operators that have an active facility in the auction will receive this report, regardless of whether there is any auction quantity won on their facility.\n\nAuction participants that have an active bid in the auction will receive this report, regardless of whether they win any capacity in the auction."},"status":"This response is provided when \"Authorisation\" is missing from the header OR user/password is incorrect/not provided OR user account is locked out.","code":401,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"6bf03d99-294a-40d6-b679-3e218e25d2f2","name":"Response_422","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportAuctionResults?FacilityId=530001&FromAuctionDate=2018-02-23&ToAuctionDate=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportAuctionResults"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"FromAuctionDate","value":"2018-02-23","description":"From Auction Date"},{"key":"ToAuctionDate","value":"2018-02-23","description":"To Auction Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity won by shippers at auction.\n\nFacility operators use this data to assign capacity of auction services to shippers.\n\nFacility operators that have an active facility in the auction will receive this report, regardless of whether there is any auction quantity won on their facility.\n\nAuction participants that have an active bid in the auction will receive this report, regardless of whether they win any capacity in the auction."},"status":"This response is provided when any there are any Business validation failures, then entire submission is rejected.","code":422,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"814035b0-bce9-4e83-a1ae-3192716b3a33","name":"Response_200","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportAuctionResults?FacilityId=530001&FromAuctionDate=2018-02-23&ToAuctionDate=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportAuctionResults"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"FromAuctionDate","value":"2018-02-23","description":"From Auction Date"},{"key":"ToAuctionDate","value":"2018-02-23","description":"To Auction Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity won by shippers at auction.\n\nFacility operators use this data to assign capacity of auction services to shippers.\n\nFacility operators that have an active facility in the auction will receive this report, regardless of whether there is any auction quantity won on their facility.\n\nAuction participants that have an active bid in the auction will receive this report, regardless of whether they win any capacity in the auction."},"status":"Successful reponse with report on capacity quantity won at auction","code":200,"_postman_previewlanguage":"Text","header":[{"key":"Content-Type","value":"application/json"}],"cookie":[],"responseTime":null,"body":"{}"},{"id":"4a3e8a24-16cd-4fc3-9933-0a3417b41f76","name":"Response_503","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportAuctionResults?FacilityId=530001&FromAuctionDate=2018-02-23&ToAuctionDate=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportAuctionResults"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"FromAuctionDate","value":"2018-02-23","description":"From Auction Date"},{"key":"ToAuctionDate","value":"2018-02-23","description":"To Auction Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity won by shippers at auction.\n\nFacility operators use this data to assign capacity of auction services to shippers.\n\nFacility operators that have an active facility in the auction will receive this report, regardless of whether there is any auction quantity won on their facility.\n\nAuction participants that have an active bid in the auction will receive this report, regardless of whether they win any capacity in the auction."},"status":"Exceeds throttling limits OR SSL Certificate authentication validation failed","code":503,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"45a596b6-7038-497b-a4b7-1cdf236b1be9","name":"Response_405","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportAuctionResults?FacilityId=530001&FromAuctionDate=2018-02-23&ToAuctionDate=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportAuctionResults"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"FromAuctionDate","value":"2018-02-23","description":"From Auction Date"},{"key":"ToAuctionDate","value":"2018-02-23","description":"To Auction Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity won by shippers at auction.\n\nFacility operators use this data to assign capacity of auction services to shippers.\n\nFacility operators that have an active facility in the auction will receive this report, regardless of whether there is any auction quantity won on their facility.\n\nAuction participants that have an active bid in the auction will receive this report, regardless of whether they win any capacity in the auction."},"status":"Invalid Method used (e.g. GET used instead of POST)","code":405,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"5a92be0e-d3bd-4b05-b9ac-e84b48c0d17b","name":"Response_404","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportAuctionResults?FacilityId=530001&FromAuctionDate=2018-02-23&ToAuctionDate=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportAuctionResults"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"FromAuctionDate","value":"2018-02-23","description":"From Auction Date"},{"key":"ToAuctionDate","value":"2018-02-23","description":"To Auction Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity won by shippers at auction.\n\nFacility operators use this data to assign capacity of auction services to shippers.\n\nFacility operators that have an active facility in the auction will receive this report, regardless of whether there is any auction quantity won on their facility.\n\nAuction participants that have an active bid in the auction will receive this report, regardless of whether they win any capacity in the auction."},"status":"This response is provided when the resource is missing from the URL or the URL is incorrect.","code":404,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"2b239234-4eed-433e-b5dc-f6cbaf14dd52","name":"Response_500","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportAuctionResults?FacilityId=530001&FromAuctionDate=2018-02-23&ToAuctionDate=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportAuctionResults"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"FromAuctionDate","value":"2018-02-23","description":"From Auction Date"},{"key":"ToAuctionDate","value":"2018-02-23","description":"To Auction Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity won by shippers at auction.\n\nFacility operators use this data to assign capacity of auction services to shippers.\n\nFacility operators that have an active facility in the auction will receive this report, regardless of whether there is any auction quantity won on their facility.\n\nAuction participants that have an active bid in the auction will receive this report, regardless of whether they win any capacity in the auction."},"status":"e-Hub is operational but downstream systems are not available.","code":500,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"35e426d4-6d7f-4389-bafc-bdd2e722d6e4","name":"Response_400","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportAuctionResults?FacilityId=530001&FromAuctionDate=2018-02-23&ToAuctionDate=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportAuctionResults"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"FromAuctionDate","value":"2018-02-23","description":"From Auction Date"},{"key":"ToAuctionDate","value":"2018-02-23","description":"To Auction Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity won by shippers at auction.\n\nFacility operators use this data to assign capacity of auction services to shippers.\n\nFacility operators that have an active facility in the auction will receive this report, regardless of whether there is any auction quantity won on their facility.\n\nAuction participants that have an active bid in the auction will receive this report, regardless of whether they win any capacity in the auction."},"status":"The service cannot be found for the endpoint reference (EPR) <URI>","code":400,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""}],"_postman_id":"eb818fbf-5110-4ae2-8a6f-c7197dd98b07"},{"name":"getReportCapacityTransferAndAuctionNotice","id":"d2518169-1fc8-4fb4-a1b1-bf2ff1993310","protocolProfileBehavior":{"disableBodyPruning":true},"request":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"<p>The ID of the Initiating Participant</p>\n"},{"key":"X-market","value":"GAS","description":"<p>The market type that the request applies.</p>\n"},{"key":"Accept","value":"application/json"}],"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferAndAuctionNotice?FacilityId=530001&Markets=CTP&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","description":"<p>The report notifies participants when the market delay or cancellation process is triggered.</p>\n","auth":{"type":"basic","basic":{"basicConfig":[]},"isInherited":true,"source":{"_postman_id":"6375289a-c484-476a-8f8e-b02a7053ecd0","id":"6375289a-c484-476a-8f8e-b02a7053ecd0","name":"capacity","type":"collection"}},"urlObject":{"path":["reportCapacityTransferAndAuctionNotice"],"host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"query":[{"description":{"content":"<p>The unique AEMO defined Facility identifier.</p>\n","type":"text/plain"},"key":"FacilityId","value":"530001"},{"description":{"content":"<p>The market that has triggered the notice, for example CTP or DAA.</p>\n","type":"text/plain"},"key":"Markets","value":"CTP"},{"description":{"content":"<p>Changed After Date</p>\n","type":"text/plain"},"key":"ChangedAfter","value":"2018-02-23"},{"description":{"content":"<p>One calendar month from request date</p>\n","type":"text/plain"},"key":"FromGasDate","value":"2018-07-01"},{"description":{"content":"<p>Request date</p>\n","type":"text/plain"},"key":"ToGasDate","value":"2018-07-01"}],"variable":[]}},"response":[{"id":"b75ed9c5-1d21-4bba-b24d-03c066db914d","name":"Response_401","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferAndAuctionNotice?FacilityId=530001&Markets=CTP&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferAndAuctionNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"Markets","value":"CTP","description":"The market that has triggered the notice, for example CTP or DAA."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"The report notifies participants when the market delay or cancellation process is triggered."},"status":"This response is provided when \"Authorisation\" is missing from the header OR user/password is incorrect/not provided OR user account is locked out.","code":401,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"91c34f0a-e5b0-4471-ae20-f0fec4d09d36","name":"Response_503","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferAndAuctionNotice?FacilityId=530001&Markets=CTP&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferAndAuctionNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"Markets","value":"CTP","description":"The market that has triggered the notice, for example CTP or DAA."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"The report notifies participants when the market delay or cancellation process is triggered."},"status":"Exceeds throttling limits OR SSL Certificate authentication validation failed","code":503,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"7e8eb192-8621-4f57-86cf-54952674a17b","name":"Response_400","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferAndAuctionNotice?FacilityId=530001&Markets=CTP&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferAndAuctionNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"Markets","value":"CTP","description":"The market that has triggered the notice, for example CTP or DAA."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"The report notifies participants when the market delay or cancellation process is triggered."},"status":"The service cannot be found for the endpoint reference (EPR) <URI>","code":400,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"d618c3d9-f85a-4381-8907-339706925fc0","name":"Response_200","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferAndAuctionNotice?FacilityId=530001&Markets=CTP&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferAndAuctionNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"Markets","value":"CTP","description":"The market that has triggered the notice, for example CTP or DAA."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"The report notifies participants when the market delay or cancellation process is triggered."},"status":"Successful reponse with report on market delay or cancellation","code":200,"_postman_previewlanguage":"Text","header":[{"key":"Content-Type","value":"application/json"}],"cookie":[],"responseTime":null,"body":"{}"},{"id":"2bd152a0-2fb6-4dd9-abb1-507aac0ff076","name":"Response_411","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferAndAuctionNotice?FacilityId=530001&Markets=CTP&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferAndAuctionNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"Markets","value":"CTP","description":"The market that has triggered the notice, for example CTP or DAA."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"The report notifies participants when the market delay or cancellation process is triggered."},"status":"This response is provided when \"Content-Length\" is missing from the Header","code":411,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"f8c34132-f872-43fe-8225-7a2e5d05a04c","name":"Response_422","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferAndAuctionNotice?FacilityId=530001&Markets=CTP&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferAndAuctionNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"Markets","value":"CTP","description":"The market that has triggered the notice, for example CTP or DAA."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"The report notifies participants when the market delay or cancellation process is triggered."},"status":"This response is provided when any there are any Business validation failures, then entire submission is rejected.","code":422,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"c3e5f36a-cfbc-477e-a75e-bfd5aa81dfb4","name":"Response_405","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferAndAuctionNotice?FacilityId=530001&Markets=CTP&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferAndAuctionNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"Markets","value":"CTP","description":"The market that has triggered the notice, for example CTP or DAA."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"The report notifies participants when the market delay or cancellation process is triggered."},"status":"Invalid Method used (e.g. GET used instead of POST)","code":405,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"c2fc24d3-7679-4a59-8f11-db1ec0580a12","name":"Response_500","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferAndAuctionNotice?FacilityId=530001&Markets=CTP&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferAndAuctionNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"Markets","value":"CTP","description":"The market that has triggered the notice, for example CTP or DAA."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"The report notifies participants when the market delay or cancellation process is triggered."},"status":"e-Hub is operational but downstream systems are not available.","code":500,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"8c724678-ade5-431e-bd4c-7246649950f2","name":"Response_404","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferAndAuctionNotice?FacilityId=530001&Markets=CTP&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferAndAuctionNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"Markets","value":"CTP","description":"The market that has triggered the notice, for example CTP or DAA."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"The report notifies participants when the market delay or cancellation process is triggered."},"status":"This response is provided when the resource is missing from the URL or the URL is incorrect.","code":404,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"95d8ed36-86ea-41d3-bc8f-32a4185cac05","name":"Response_403","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferAndAuctionNotice?FacilityId=530001&Markets=CTP&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferAndAuctionNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"Markets","value":"CTP","description":"The market that has triggered the notice, for example CTP or DAA."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"The report notifies participants when the market delay or cancellation process is triggered."},"status":"This response is provided when there is an invalid Role i.e. user does not have permission to submit this request.","code":403,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""}],"_postman_id":"d2518169-1fc8-4fb4-a1b1-bf2ff1993310"},{"name":"getReportCapacityTransferNotice","id":"90df6ef7-599e-4b26-852a-ef321f699ede","protocolProfileBehavior":{"disableBodyPruning":true},"request":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"<p>The ID of the Initiating Participant</p>\n"},{"key":"X-market","value":"GAS","description":"<p>The market type that the request applies.</p>\n"},{"key":"Accept","value":"application/json"}],"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferNotice?FacilityId=530001&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","description":"<p>Provide the capacity quantity adjustment required for a shipper contract.</p>\n<p>Facility operators use this data to update the capacity quantity on the relevant shipper contracts in their own systems.</p>\n<p>Each published version of the data contains both the incremental adjustment quantity and the cumulative/overall adjustment quantity that must be applied to a shipper’s contracted capacity quantity, on the same day that this report is published.</p>\n<p>Park product transfers are identified by empty zone details and identical receipt and delivery points.</p>\n","auth":{"type":"basic","basic":{"basicConfig":[]},"isInherited":true,"source":{"_postman_id":"6375289a-c484-476a-8f8e-b02a7053ecd0","id":"6375289a-c484-476a-8f8e-b02a7053ecd0","name":"capacity","type":"collection"}},"urlObject":{"path":["reportCapacityTransferNotice"],"host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"query":[{"description":{"content":"<p>The unique AEMO defined Facility identifier.</p>\n","type":"text/plain"},"key":"FacilityId","value":"530001"},{"description":{"content":"<p>Changed After Date</p>\n","type":"text/plain"},"key":"ChangedAfter","value":"2018-02-23"},{"description":{"content":"<p>One calendar month from request date</p>\n","type":"text/plain"},"key":"FromGasDate","value":"2018-07-01"},{"description":{"content":"<p>Request date</p>\n","type":"text/plain"},"key":"ToGasDate","value":"2018-07-01"}],"variable":[]}},"response":[{"id":"387104f6-3174-411e-b194-8132864095b2","name":"Response_404","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferNotice?FacilityId=530001&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity adjustment required for a shipper contract.\n\nFacility operators use this data to update the capacity quantity on the relevant shipper contracts in their own systems.\n\nEach published version of the data contains both the incremental adjustment quantity and the cumulative/overall adjustment quantity that must be applied to a shipper’s contracted capacity quantity, on the same day that this report is published.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"This response is provided when the resource is missing from the URL or the URL is incorrect.","code":404,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"6736a615-a4f7-452e-94d7-2d4c300a934b","name":"Response_200","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferNotice?FacilityId=530001&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity adjustment required for a shipper contract.\n\nFacility operators use this data to update the capacity quantity on the relevant shipper contracts in their own systems.\n\nEach published version of the data contains both the incremental adjustment quantity and the cumulative/overall adjustment quantity that must be applied to a shipper’s contracted capacity quantity, on the same day that this report is published.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"Successful reponse with report on capacity transfer notice","code":200,"_postman_previewlanguage":"Text","header":[{"key":"Content-Type","value":"application/json"}],"cookie":[],"responseTime":null,"body":"{}"},{"id":"4d7c5ed0-de26-40c5-94ef-182043946d89","name":"Response_500","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferNotice?FacilityId=530001&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity adjustment required for a shipper contract.\n\nFacility operators use this data to update the capacity quantity on the relevant shipper contracts in their own systems.\n\nEach published version of the data contains both the incremental adjustment quantity and the cumulative/overall adjustment quantity that must be applied to a shipper’s contracted capacity quantity, on the same day that this report is published.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"e-Hub is operational but downstream systems are not available.","code":500,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"58012e60-8164-4f62-9ec5-747e3cc29e0a","name":"Response_403","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferNotice?FacilityId=530001&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity adjustment required for a shipper contract.\n\nFacility operators use this data to update the capacity quantity on the relevant shipper contracts in their own systems.\n\nEach published version of the data contains both the incremental adjustment quantity and the cumulative/overall adjustment quantity that must be applied to a shipper’s contracted capacity quantity, on the same day that this report is published.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"This response is provided when there is an invalid Role i.e. user does not have permission to submit this request.","code":403,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"da1d2c1d-d4ea-4ba0-993b-13916780de8c","name":"Response_405","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferNotice?FacilityId=530001&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity adjustment required for a shipper contract.\n\nFacility operators use this data to update the capacity quantity on the relevant shipper contracts in their own systems.\n\nEach published version of the data contains both the incremental adjustment quantity and the cumulative/overall adjustment quantity that must be applied to a shipper’s contracted capacity quantity, on the same day that this report is published.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"Invalid Method used (e.g. GET used instead of POST)","code":405,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"6f438d96-a9fe-4375-b7fe-cad58e756d43","name":"Response_422","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferNotice?FacilityId=530001&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity adjustment required for a shipper contract.\n\nFacility operators use this data to update the capacity quantity on the relevant shipper contracts in their own systems.\n\nEach published version of the data contains both the incremental adjustment quantity and the cumulative/overall adjustment quantity that must be applied to a shipper’s contracted capacity quantity, on the same day that this report is published.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"This response is provided when any there are any Business validation failures, then entire submission is rejected.","code":422,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"d3902dfc-8304-4460-bf01-184abde07d12","name":"Response_401","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferNotice?FacilityId=530001&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity adjustment required for a shipper contract.\n\nFacility operators use this data to update the capacity quantity on the relevant shipper contracts in their own systems.\n\nEach published version of the data contains both the incremental adjustment quantity and the cumulative/overall adjustment quantity that must be applied to a shipper’s contracted capacity quantity, on the same day that this report is published.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"This response is provided when \"Authorisation\" is missing from the header OR user/password is incorrect/not provided OR user account is locked out.","code":401,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"9a170c68-ab56-43a2-aac3-9f9585e8ec34","name":"Response_400","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferNotice?FacilityId=530001&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity adjustment required for a shipper contract.\n\nFacility operators use this data to update the capacity quantity on the relevant shipper contracts in their own systems.\n\nEach published version of the data contains both the incremental adjustment quantity and the cumulative/overall adjustment quantity that must be applied to a shipper’s contracted capacity quantity, on the same day that this report is published.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"The service cannot be found for the endpoint reference (EPR) <URI>","code":400,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"b3bc917e-9fce-4436-95cb-0517a21cb012","name":"Response_411","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferNotice?FacilityId=530001&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity adjustment required for a shipper contract.\n\nFacility operators use this data to update the capacity quantity on the relevant shipper contracts in their own systems.\n\nEach published version of the data contains both the incremental adjustment quantity and the cumulative/overall adjustment quantity that must be applied to a shipper’s contracted capacity quantity, on the same day that this report is published.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"This response is provided when \"Content-Length\" is missing from the Header","code":411,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"6d2455f2-b863-4148-b621-d9321d55a1c0","name":"Response_503","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportCapacityTransferNotice?FacilityId=530001&ChangedAfter=2018-02-23&FromGasDate=2018-07-01&ToGasDate=2018-07-01","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportCapacityTransferNotice"],"query":[{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"},{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"}]},"description":"Provide the capacity quantity adjustment required for a shipper contract.\n\nFacility operators use this data to update the capacity quantity on the relevant shipper contracts in their own systems.\n\nEach published version of the data contains both the incremental adjustment quantity and the cumulative/overall adjustment quantity that must be applied to a shipper’s contracted capacity quantity, on the same day that this report is published.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"Exceeds throttling limits OR SSL Certificate authentication validation failed","code":503,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""}],"_postman_id":"90df6ef7-599e-4b26-852a-ef321f699ede"},{"name":"getReportRegisteredParticipant","id":"43dff964-d64b-44f1-9a69-4d1c30e282cb","protocolProfileBehavior":{"disableBodyPruning":true},"request":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"<p>The ID of the Initiating Participant</p>\n"},{"key":"X-market","value":"GAS","description":"<p>The market type that the request applies.</p>\n"},{"key":"Accept","value":"application/json"}],"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportRegisteredParticipants?Markets=\"Gas Supply Hub\"","description":"<p>The report contains the registration details of all participants currently registered in the GSH, CTP and DAA markets.</p>\n","auth":{"type":"basic","basic":{"basicConfig":[]},"isInherited":true,"source":{"_postman_id":"6375289a-c484-476a-8f8e-b02a7053ecd0","id":"6375289a-c484-476a-8f8e-b02a7053ecd0","name":"capacity","type":"collection"}},"urlObject":{"path":["reportRegisteredParticipants"],"host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"query":[{"description":{"content":"<p>The market in which the company is a participant, for example Gas Supply Hub or Gas Capacity Auction. Companies that participate in both markets have a separate row displayed for each market.</p>\n","type":"text/plain"},"key":"Markets","value":"\"Gas Supply Hub\""}],"variable":[]}},"response":[{"id":"8a6c344e-c6d3-4a77-b653-c704444f00ba","name":"Response_200","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportRegisteredParticipants?Markets=\"Gas Supply Hub\"","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportRegisteredParticipants"],"query":[{"key":"Markets","value":"\"Gas Supply Hub\"","description":"The market in which the company is a participant, for example Gas Supply Hub or Gas Capacity Auction. Companies that participate in both markets have a separate row displayed for each market."}]},"description":"The report contains the registration details of all participants currently registered in the GSH, CTP and DAA markets."},"status":"Successful reponse with registered participants report","code":200,"_postman_previewlanguage":"Text","header":[{"key":"Content-Type","value":"application/json"}],"cookie":[],"responseTime":null,"body":"{}"},{"id":"b13820c1-9e7c-4fb8-93ba-200386c03f1b","name":"Response_405","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportRegisteredParticipants?Markets=\"Gas Supply Hub\"","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportRegisteredParticipants"],"query":[{"key":"Markets","value":"\"Gas Supply Hub\"","description":"The market in which the company is a participant, for example Gas Supply Hub or Gas Capacity Auction. Companies that participate in both markets have a separate row displayed for each market."}]},"description":"The report contains the registration details of all participants currently registered in the GSH, CTP and DAA markets."},"status":"Invalid Method used (e.g. GET used instead of POST)","code":405,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"13ad2628-6401-4018-b34a-5f920547a06f","name":"Response_400","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportRegisteredParticipants?Markets=\"Gas Supply Hub\"","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportRegisteredParticipants"],"query":[{"key":"Markets","value":"\"Gas Supply Hub\"","description":"The market in which the company is a participant, for example Gas Supply Hub or Gas Capacity Auction. Companies that participate in both markets have a separate row displayed for each market."}]},"description":"The report contains the registration details of all participants currently registered in the GSH, CTP and DAA markets."},"status":"The service cannot be found for the endpoint reference (EPR) <URI>","code":400,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"27371f6f-9569-4417-8f3c-5b0c451692e4","name":"Response_422","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportRegisteredParticipants?Markets=\"Gas Supply Hub\"","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportRegisteredParticipants"],"query":[{"key":"Markets","value":"\"Gas Supply Hub\"","description":"The market in which the company is a participant, for example Gas Supply Hub or Gas Capacity Auction. Companies that participate in both markets have a separate row displayed for each market."}]},"description":"The report contains the registration details of all participants currently registered in the GSH, CTP and DAA markets."},"status":"This response is provided when any there are any Business validation failures, then entire submission is rejected.","code":422,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"35247c12-91a2-4483-afe9-70d1dcacb093","name":"Response_403","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportRegisteredParticipants?Markets=\"Gas Supply Hub\"","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportRegisteredParticipants"],"query":[{"key":"Markets","value":"\"Gas Supply Hub\"","description":"The market in which the company is a participant, for example Gas Supply Hub or Gas Capacity Auction. Companies that participate in both markets have a separate row displayed for each market."}]},"description":"The report contains the registration details of all participants currently registered in the GSH, CTP and DAA markets."},"status":"This response is provided when there is an invalid Role i.e. user does not have permission to submit this request.","code":403,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"92b75c0c-b5cc-46aa-bf84-c225ec6efbef","name":"Response_404","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportRegisteredParticipants?Markets=\"Gas Supply Hub\"","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportRegisteredParticipants"],"query":[{"key":"Markets","value":"\"Gas Supply Hub\"","description":"The market in which the company is a participant, for example Gas Supply Hub or Gas Capacity Auction. Companies that participate in both markets have a separate row displayed for each market."}]},"description":"The report contains the registration details of all participants currently registered in the GSH, CTP and DAA markets."},"status":"This response is provided when the resource is missing from the URL or the URL is incorrect.","code":404,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"25d55711-4e33-4026-84d1-bb8bec11ce00","name":"Response_411","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportRegisteredParticipants?Markets=\"Gas Supply Hub\"","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportRegisteredParticipants"],"query":[{"key":"Markets","value":"\"Gas Supply Hub\"","description":"The market in which the company is a participant, for example Gas Supply Hub or Gas Capacity Auction. Companies that participate in both markets have a separate row displayed for each market."}]},"description":"The report contains the registration details of all participants currently registered in the GSH, CTP and DAA markets."},"status":"This response is provided when \"Content-Length\" is missing from the Header","code":411,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"f94c25d4-5d29-43d5-963a-8f5c83df0b59","name":"Response_503","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportRegisteredParticipants?Markets=\"Gas Supply Hub\"","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportRegisteredParticipants"],"query":[{"key":"Markets","value":"\"Gas Supply Hub\"","description":"The market in which the company is a participant, for example Gas Supply Hub or Gas Capacity Auction. Companies that participate in both markets have a separate row displayed for each market."}]},"description":"The report contains the registration details of all participants currently registered in the GSH, CTP and DAA markets."},"status":"Exceeds throttling limits OR SSL Certificate authentication validation failed","code":503,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"58430491-3af5-43dd-98ba-f52cca716011","name":"Response_500","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportRegisteredParticipants?Markets=\"Gas Supply Hub\"","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportRegisteredParticipants"],"query":[{"key":"Markets","value":"\"Gas Supply Hub\"","description":"The market in which the company is a participant, for example Gas Supply Hub or Gas Capacity Auction. Companies that participate in both markets have a separate row displayed for each market."}]},"description":"The report contains the registration details of all participants currently registered in the GSH, CTP and DAA markets."},"status":"e-Hub is operational but downstream systems are not available.","code":500,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"4d5a5995-b52c-4d50-b31b-cb41d19c249c","name":"Response_401","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportRegisteredParticipants?Markets=\"Gas Supply Hub\"","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportRegisteredParticipants"],"query":[{"key":"Markets","value":"\"Gas Supply Hub\"","description":"The market in which the company is a participant, for example Gas Supply Hub or Gas Capacity Auction. Companies that participate in both markets have a separate row displayed for each market."}]},"description":"The report contains the registration details of all participants currently registered in the GSH, CTP and DAA markets."},"status":"This response is provided when \"Authorisation\" is missing from the header OR user/password is incorrect/not provided OR user account is locked out.","code":401,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""}],"_postman_id":"43dff964-d64b-44f1-9a69-4d1c30e282cb"},{"name":"getReportShipperCapacityTransferNotification","id":"9ca5d325-f28d-4fcc-aa24-2549f0c6df22","protocolProfileBehavior":{"disableBodyPruning":true},"request":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"<p>The ID of the Initiating Participant</p>\n"},{"key":"X-market","value":"GAS","description":"<p>The market type that the request applies.</p>\n"},{"key":"Accept","value":"application/json"}],"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportShipperCapacityTransferNotification?FromGasDate=2018-07-01&ToGasDate=2018-07-01&ChangedAfter=2018-02-23","description":"<p>Provide confirmation to facility operator that shipper is notified of a capacity transfer outcome.\nFailed capacity transfer can be due to-</p>\n<ul>\n<li><p>Facility operator system failure preventing the capacity transfer in their system.</p>\n</li>\n<li><p>Facility operator system rejects the capacity transfer due to an issue with the contract specified.</p>\n</li>\n<li><p>AEMO system failure preventing the capacity transfer in the STTM or DWGM system.</p>\n</li>\n<li><p>AEMO STTM or DWGM system rejects the capacity transfer due to an issue with the STTM registered facility service (CRN) or DWGM accreditation reference specified.</p>\n</li>\n</ul>\n<p>Park product transfers are identified by empty zone details and identical receipt and delivery points.</p>\n","auth":{"type":"basic","basic":{"basicConfig":[]},"isInherited":true,"source":{"_postman_id":"6375289a-c484-476a-8f8e-b02a7053ecd0","id":"6375289a-c484-476a-8f8e-b02a7053ecd0","name":"capacity","type":"collection"}},"urlObject":{"path":["reportShipperCapacityTransferNotification"],"host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"query":[{"description":{"content":"<p>One calendar month from request date</p>\n","type":"text/plain"},"key":"FromGasDate","value":"2018-07-01"},{"description":{"content":"<p>Request date</p>\n","type":"text/plain"},"key":"ToGasDate","value":"2018-07-01"},{"description":{"content":"<p>Changed After Date</p>\n","type":"text/plain"},"key":"ChangedAfter","value":"2018-02-23"}],"variable":[]}},"response":[{"id":"226e0fd3-d15b-4715-8713-f4fe61513e9d","name":"Response_200","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportShipperCapacityTransferNotification?FromGasDate=2018-07-01&ToGasDate=2018-07-01&ChangedAfter=2018-02-23","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportShipperCapacityTransferNotification"],"query":[{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"}]},"description":"Provide confirmation to facility operator that shipper is notified of a capacity transfer outcome.\nFailed capacity transfer can be due to-\n\n- Facility operator system failure preventing the capacity transfer in their system.\n\n- Facility operator system rejects the capacity transfer due to an issue with the contract specified.\n\n- AEMO system failure preventing the capacity transfer in the STTM or DWGM system.\n\n- AEMO STTM or DWGM system rejects the capacity transfer due to an issue with the STTM registered facility service (CRN) or DWGM accreditation reference specified.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"Successful reponse Shipper Capacity Transfer report","code":200,"_postman_previewlanguage":"Text","header":[{"key":"Content-Type","value":"application/json"}],"cookie":[],"responseTime":null,"body":"{}"},{"id":"24ca0a6e-ad1b-480c-9278-07752be1ca24","name":"Response_403","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportShipperCapacityTransferNotification?FromGasDate=2018-07-01&ToGasDate=2018-07-01&ChangedAfter=2018-02-23","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportShipperCapacityTransferNotification"],"query":[{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"}]},"description":"Provide confirmation to facility operator that shipper is notified of a capacity transfer outcome.\nFailed capacity transfer can be due to-\n\n- Facility operator system failure preventing the capacity transfer in their system.\n\n- Facility operator system rejects the capacity transfer due to an issue with the contract specified.\n\n- AEMO system failure preventing the capacity transfer in the STTM or DWGM system.\n\n- AEMO STTM or DWGM system rejects the capacity transfer due to an issue with the STTM registered facility service (CRN) or DWGM accreditation reference specified.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"This response is provided when there is an invalid Role i.e. user does not have permission to submit this request.","code":403,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"55d1c433-efd3-41b1-9c41-a6e4f0ca6434","name":"Response_401","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportShipperCapacityTransferNotification?FromGasDate=2018-07-01&ToGasDate=2018-07-01&ChangedAfter=2018-02-23","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportShipperCapacityTransferNotification"],"query":[{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"}]},"description":"Provide confirmation to facility operator that shipper is notified of a capacity transfer outcome.\nFailed capacity transfer can be due to-\n\n- Facility operator system failure preventing the capacity transfer in their system.\n\n- Facility operator system rejects the capacity transfer due to an issue with the contract specified.\n\n- AEMO system failure preventing the capacity transfer in the STTM or DWGM system.\n\n- AEMO STTM or DWGM system rejects the capacity transfer due to an issue with the STTM registered facility service (CRN) or DWGM accreditation reference specified.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"This response is provided when \"Authorisation\" is missing from the header OR user/password is incorrect/not provided OR user account is locked out.","code":401,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"acd3e4d7-7166-4d1c-80c2-3811ce0a3c52","name":"Response_411","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportShipperCapacityTransferNotification?FromGasDate=2018-07-01&ToGasDate=2018-07-01&ChangedAfter=2018-02-23","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportShipperCapacityTransferNotification"],"query":[{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"}]},"description":"Provide confirmation to facility operator that shipper is notified of a capacity transfer outcome.\nFailed capacity transfer can be due to-\n\n- Facility operator system failure preventing the capacity transfer in their system.\n\n- Facility operator system rejects the capacity transfer due to an issue with the contract specified.\n\n- AEMO system failure preventing the capacity transfer in the STTM or DWGM system.\n\n- AEMO STTM or DWGM system rejects the capacity transfer due to an issue with the STTM registered facility service (CRN) or DWGM accreditation reference specified.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"This response is provided when \"Content-Length\" is missing from the Header","code":411,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"77ac51d5-19fa-4829-8c3f-7b8f80bf6196","name":"Response_422","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportShipperCapacityTransferNotification?FromGasDate=2018-07-01&ToGasDate=2018-07-01&ChangedAfter=2018-02-23","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportShipperCapacityTransferNotification"],"query":[{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"}]},"description":"Provide confirmation to facility operator that shipper is notified of a capacity transfer outcome.\nFailed capacity transfer can be due to-\n\n- Facility operator system failure preventing the capacity transfer in their system.\n\n- Facility operator system rejects the capacity transfer due to an issue with the contract specified.\n\n- AEMO system failure preventing the capacity transfer in the STTM or DWGM system.\n\n- AEMO STTM or DWGM system rejects the capacity transfer due to an issue with the STTM registered facility service (CRN) or DWGM accreditation reference specified.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"This response is provided when any there are any Business validation failures, then entire submission is rejected.","code":422,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"a01879fc-89e8-4af8-bece-98470fc935e1","name":"Response_400","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportShipperCapacityTransferNotification?FromGasDate=2018-07-01&ToGasDate=2018-07-01&ChangedAfter=2018-02-23","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportShipperCapacityTransferNotification"],"query":[{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"}]},"description":"Provide confirmation to facility operator that shipper is notified of a capacity transfer outcome.\nFailed capacity transfer can be due to-\n\n- Facility operator system failure preventing the capacity transfer in their system.\n\n- Facility operator system rejects the capacity transfer due to an issue with the contract specified.\n\n- AEMO system failure preventing the capacity transfer in the STTM or DWGM system.\n\n- AEMO STTM or DWGM system rejects the capacity transfer due to an issue with the STTM registered facility service (CRN) or DWGM accreditation reference specified.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"The service cannot be found for the endpoint reference (EPR) <URI>","code":400,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"dcebc793-db3e-4ffe-a449-c73690c8187e","name":"Response_503","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportShipperCapacityTransferNotification?FromGasDate=2018-07-01&ToGasDate=2018-07-01&ChangedAfter=2018-02-23","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportShipperCapacityTransferNotification"],"query":[{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"}]},"description":"Provide confirmation to facility operator that shipper is notified of a capacity transfer outcome.\nFailed capacity transfer can be due to-\n\n- Facility operator system failure preventing the capacity transfer in their system.\n\n- Facility operator system rejects the capacity transfer due to an issue with the contract specified.\n\n- AEMO system failure preventing the capacity transfer in the STTM or DWGM system.\n\n- AEMO STTM or DWGM system rejects the capacity transfer due to an issue with the STTM registered facility service (CRN) or DWGM accreditation reference specified.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"Exceeds throttling limits OR SSL Certificate authentication validation failed","code":503,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"5959da0d-ad1a-42bc-b62b-4ec1ef91eab9","name":"Response_405","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportShipperCapacityTransferNotification?FromGasDate=2018-07-01&ToGasDate=2018-07-01&ChangedAfter=2018-02-23","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportShipperCapacityTransferNotification"],"query":[{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"}]},"description":"Provide confirmation to facility operator that shipper is notified of a capacity transfer outcome.\nFailed capacity transfer can be due to-\n\n- Facility operator system failure preventing the capacity transfer in their system.\n\n- Facility operator system rejects the capacity transfer due to an issue with the contract specified.\n\n- AEMO system failure preventing the capacity transfer in the STTM or DWGM system.\n\n- AEMO STTM or DWGM system rejects the capacity transfer due to an issue with the STTM registered facility service (CRN) or DWGM accreditation reference specified.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"Invalid Method used (e.g. GET used instead of POST)","code":405,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"1a8f6b97-ad0e-46cc-8880-8a619fbab2c2","name":"Response_404","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportShipperCapacityTransferNotification?FromGasDate=2018-07-01&ToGasDate=2018-07-01&ChangedAfter=2018-02-23","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportShipperCapacityTransferNotification"],"query":[{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"}]},"description":"Provide confirmation to facility operator that shipper is notified of a capacity transfer outcome.\nFailed capacity transfer can be due to-\n\n- Facility operator system failure preventing the capacity transfer in their system.\n\n- Facility operator system rejects the capacity transfer due to an issue with the contract specified.\n\n- AEMO system failure preventing the capacity transfer in the STTM or DWGM system.\n\n- AEMO STTM or DWGM system rejects the capacity transfer due to an issue with the STTM registered facility service (CRN) or DWGM accreditation reference specified.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"This response is provided when the resource is missing from the URL or the URL is incorrect.","code":404,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"d778c43a-e910-41f7-92ce-b052800e7c76","name":"Response_500","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportShipperCapacityTransferNotification?FromGasDate=2018-07-01&ToGasDate=2018-07-01&ChangedAfter=2018-02-23","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportShipperCapacityTransferNotification"],"query":[{"key":"FromGasDate","value":"2018-07-01","description":"One calendar month from request date"},{"key":"ToGasDate","value":"2018-07-01","description":"Request date"},{"key":"ChangedAfter","value":"2018-02-23","description":"Changed After Date"}]},"description":"Provide confirmation to facility operator that shipper is notified of a capacity transfer outcome.\nFailed capacity transfer can be due to-\n\n- Facility operator system failure preventing the capacity transfer in their system.\n\n- Facility operator system rejects the capacity transfer due to an issue with the contract specified.\n\n- AEMO system failure preventing the capacity transfer in the STTM or DWGM system.\n\n- AEMO STTM or DWGM system rejects the capacity transfer due to an issue with the STTM registered facility service (CRN) or DWGM accreditation reference specified.\n\nPark product transfers are identified by empty zone details and identical receipt and delivery points."},"status":"e-Hub is operational but downstream systems are not available.","code":500,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""}],"_postman_id":"9ca5d325-f28d-4fcc-aa24-2549f0c6df22"},{"name":"getReportTransportationFacilityRegister","id":"2be4268d-9e2b-4c2f-8980-8b3a7d5c4599","protocolProfileBehavior":{"disableBodyPruning":true},"request":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"<p>The ID of the Initiating Participant</p>\n"},{"key":"X-market","value":"GAS","description":"<p>The market type that the request applies.</p>\n"},{"key":"Accept","value":"application/json"}],"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationFacilityRegister?OperatorIds=584&FacilityId=530001","description":"<p>The report contains a list of all the facilities currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction.</p>\n","auth":{"type":"basic","basic":{"basicConfig":[]},"isInherited":true,"source":{"_postman_id":"6375289a-c484-476a-8f8e-b02a7053ecd0","id":"6375289a-c484-476a-8f8e-b02a7053ecd0","name":"capacity","type":"collection"}},"urlObject":{"path":["reportTransportationFacilityRegister"],"host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"query":[{"description":{"content":"<p>The unique identifier of the Facility Operator that operates the facility.</p>\n","type":"text/plain"},"key":"OperatorIds","value":"584"},{"description":{"content":"<p>The unique AEMO defined Facility identifier.</p>\n","type":"text/plain"},"key":"FacilityId","value":"530001"}],"variable":[]}},"response":[{"id":"c12df6aa-390d-4515-9047-7bc074aab34a","name":"Response_503","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationFacilityRegister?OperatorIds=584&FacilityId=530001","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationFacilityRegister"],"query":[{"key":"OperatorIds","value":"584","description":"The unique identifier of the Facility Operator that operates the facility."},{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."}]},"description":"The report contains a list of all the facilities currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"Exceeds throttling limits OR SSL Certificate authentication validation failed","code":503,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"577dc279-236d-4994-b352-addd2b249bfe","name":"Response_404","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationFacilityRegister?OperatorIds=584&FacilityId=530001","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationFacilityRegister"],"query":[{"key":"OperatorIds","value":"584","description":"The unique identifier of the Facility Operator that operates the facility."},{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."}]},"description":"The report contains a list of all the facilities currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"This response is provided when the resource is missing from the URL or the URL is incorrect.","code":404,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"7d8eacf8-8b51-4db9-854f-f52a28da2ab1","name":"Response_400","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationFacilityRegister?OperatorIds=584&FacilityId=530001","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationFacilityRegister"],"query":[{"key":"OperatorIds","value":"584","description":"The unique identifier of the Facility Operator that operates the facility."},{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."}]},"description":"The report contains a list of all the facilities currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"The service cannot be found for the endpoint reference (EPR) <URI>","code":400,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"b09fb527-64b8-499d-b81f-85e7ce32df0c","name":"Response_411","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationFacilityRegister?OperatorIds=584&FacilityId=530001","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationFacilityRegister"],"query":[{"key":"OperatorIds","value":"584","description":"The unique identifier of the Facility Operator that operates the facility."},{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."}]},"description":"The report contains a list of all the facilities currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"This response is provided when \"Content-Length\" is missing from the Header","code":411,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"0f147165-edec-48e8-a110-c789aba54787","name":"Response_500","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationFacilityRegister?OperatorIds=584&FacilityId=530001","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationFacilityRegister"],"query":[{"key":"OperatorIds","value":"584","description":"The unique identifier of the Facility Operator that operates the facility."},{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."}]},"description":"The report contains a list of all the facilities currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"e-Hub is operational but downstream systems are not available.","code":500,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"42aa9c69-9a0f-42bb-a493-0faa1baaa7dc","name":"Response_403","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationFacilityRegister?OperatorIds=584&FacilityId=530001","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationFacilityRegister"],"query":[{"key":"OperatorIds","value":"584","description":"The unique identifier of the Facility Operator that operates the facility."},{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."}]},"description":"The report contains a list of all the facilities currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"This response is provided when there is an invalid Role i.e. user does not have permission to submit this request.","code":403,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"f1578e4c-2978-4ded-a6fb-9f9e8b4f3589","name":"Response_422","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationFacilityRegister?OperatorIds=584&FacilityId=530001","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationFacilityRegister"],"query":[{"key":"OperatorIds","value":"584","description":"The unique identifier of the Facility Operator that operates the facility."},{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."}]},"description":"The report contains a list of all the facilities currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"This response is provided when any there are any Business validation failures, then entire submission is rejected.","code":422,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"cb5e174b-81d5-4621-9a6c-d2a5f261e358","name":"Response_405","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationFacilityRegister?OperatorIds=584&FacilityId=530001","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationFacilityRegister"],"query":[{"key":"OperatorIds","value":"584","description":"The unique identifier of the Facility Operator that operates the facility."},{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."}]},"description":"The report contains a list of all the facilities currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"Invalid Method used (e.g. GET used instead of POST)","code":405,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"0e513215-c4c5-4ae4-91ba-a3aa908fa2dd","name":"Response_401","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationFacilityRegister?OperatorIds=584&FacilityId=530001","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationFacilityRegister"],"query":[{"key":"OperatorIds","value":"584","description":"The unique identifier of the Facility Operator that operates the facility."},{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."}]},"description":"The report contains a list of all the facilities currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"This response is provided when \"Authorisation\" is missing from the header OR user/password is incorrect/not provided OR user account is locked out.","code":401,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"ae3c7783-34f5-4195-9c21-86a8e5798684","name":"Response_200","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationFacilityRegister?OperatorIds=584&FacilityId=530001","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationFacilityRegister"],"query":[{"key":"OperatorIds","value":"584","description":"The unique identifier of the Facility Operator that operates the facility."},{"key":"FacilityId","value":"530001","description":"The unique AEMO defined Facility identifier."}]},"description":"The report contains a list of all the facilities currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"Successful reponse with the Transportation facilities report","code":200,"_postman_previewlanguage":"Text","header":[{"key":"Content-Type","value":"application/json"}],"cookie":[],"responseTime":null,"body":"{}"}],"_postman_id":"2be4268d-9e2b-4c2f-8980-8b3a7d5c4599"},{"name":"getReportTransportationServicePointRegister","id":"c5f7ebd3-edc7-4b90-8603-46bf9a08db25","protocolProfileBehavior":{"disableBodyPruning":true},"request":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"<p>The ID of the Initiating Participant</p>\n"},{"key":"X-market","value":"GAS","description":"<p>The market type that the request applies.</p>\n"},{"key":"Accept","value":"application/json"}],"url":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationServicePointRegister?ComponentType=NOTIONAL_POINT","description":"<p>The report contains list of all the service points (receipt and delivery points), zones and pipeline segments currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction.</p>\n","auth":{"type":"basic","basic":{"basicConfig":[]},"isInherited":true,"source":{"_postman_id":"6375289a-c484-476a-8f8e-b02a7053ecd0","id":"6375289a-c484-476a-8f8e-b02a7053ecd0","name":"capacity","type":"collection"}},"urlObject":{"path":["reportTransportationServicePointRegister"],"host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"query":[{"description":{"content":"<p>Type of component</p>\n","type":"text/plain"},"key":"ComponentType","value":"NOTIONAL_POINT"}],"variable":[]}},"response":[{"id":"d109a9e0-cbc5-429a-8d51-54d3311213d0","name":"Response_400","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationServicePointRegister?ComponentType=NOTIONAL_POINT","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationServicePointRegister"],"query":[{"key":"ComponentType","value":"NOTIONAL_POINT","description":"Type of component"}]},"description":"The report contains list of all the service points (receipt and delivery points), zones and pipeline segments currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"The service cannot be found for the endpoint reference (EPR) <URI>","code":400,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"8b88fd94-b0fb-4710-97c4-bc4a05e181c8","name":"Response_411","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationServicePointRegister?ComponentType=NOTIONAL_POINT","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationServicePointRegister"],"query":[{"key":"ComponentType","value":"NOTIONAL_POINT","description":"Type of component"}]},"description":"The report contains list of all the service points (receipt and delivery points), zones and pipeline segments currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"This response is provided when \"Content-Length\" is missing from the Header","code":411,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"578284a2-4643-4b78-9866-ae0d3b7414a9","name":"Response_405","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationServicePointRegister?ComponentType=NOTIONAL_POINT","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationServicePointRegister"],"query":[{"key":"ComponentType","value":"NOTIONAL_POINT","description":"Type of component"}]},"description":"The report contains list of all the service points (receipt and delivery points), zones and pipeline segments currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"Invalid Method used (e.g. GET used instead of POST)","code":405,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"598201af-3296-4294-a014-2c4d3116945e","name":"Response_401","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationServicePointRegister?ComponentType=NOTIONAL_POINT","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationServicePointRegister"],"query":[{"key":"ComponentType","value":"NOTIONAL_POINT","description":"Type of component"}]},"description":"The report contains list of all the service points (receipt and delivery points), zones and pipeline segments currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"This response is provided when \"Authorisation\" is missing from the header OR user/password is incorrect/not provided OR user account is locked out.","code":401,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"ed9ed77c-c96b-4de6-b183-b0663ae16b0d","name":"Response_503","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationServicePointRegister?ComponentType=NOTIONAL_POINT","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationServicePointRegister"],"query":[{"key":"ComponentType","value":"NOTIONAL_POINT","description":"Type of component"}]},"description":"The report contains list of all the service points (receipt and delivery points), zones and pipeline segments currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"Exceeds throttling limits OR SSL Certificate authentication validation failed","code":503,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"1d8ece9b-de2c-4853-a17c-28a5c6c05c86","name":"Response_200","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationServicePointRegister?ComponentType=NOTIONAL_POINT","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationServicePointRegister"],"query":[{"key":"ComponentType","value":"NOTIONAL_POINT","description":"Type of component"}]},"description":"The report contains list of all the service points (receipt and delivery points), zones and pipeline segments currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"Successful reponse with the Transportation facilities report","code":200,"_postman_previewlanguage":"Text","header":[{"key":"Content-Type","value":"application/json"}],"cookie":[],"responseTime":null,"body":"{}"},{"id":"772c3141-45ee-47ce-a120-db76ae85ef2d","name":"Response_404","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationServicePointRegister?ComponentType=NOTIONAL_POINT","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationServicePointRegister"],"query":[{"key":"ComponentType","value":"NOTIONAL_POINT","description":"Type of component"}]},"description":"The report contains list of all the service points (receipt and delivery points), zones and pipeline segments currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"This response is provided when the resource is missing from the URL or the URL is incorrect.","code":404,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"13af06c4-4105-4cbd-8656-2ceab1dd35af","name":"Response_422","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationServicePointRegister?ComponentType=NOTIONAL_POINT","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationServicePointRegister"],"query":[{"key":"ComponentType","value":"NOTIONAL_POINT","description":"Type of component"}]},"description":"The report contains list of all the service points (receipt and delivery points), zones and pipeline segments currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"This response is provided when any there are any Business validation failures, then entire submission is rejected.","code":422,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"43269252-90ac-4a7d-9aee-c213370a06d8","name":"Response_403","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationServicePointRegister?ComponentType=NOTIONAL_POINT","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationServicePointRegister"],"query":[{"key":"ComponentType","value":"NOTIONAL_POINT","description":"Type of component"}]},"description":"The report contains list of all the service points (receipt and delivery points), zones and pipeline segments currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"This response is provided when there is an invalid Role i.e. user does not have permission to submit this request.","code":403,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""},{"id":"a27488eb-bc38-4d73-a98f-bbb80cc27c87","name":"Response_500","originalRequest":{"method":"GET","header":[{"key":"X-initiatingParticipantID","value":"ENERGYCO1","description":"The ID of the Initiating Participant"},{"key":"X-market","value":"GAS","description":"The market type that the request applies."},{"key":"Accept","value":"application/json"}],"url":{"raw":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1/reportTransportationServicePointRegister?ComponentType=NOTIONAL_POINT","host":["https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"],"path":["reportTransportationServicePointRegister"],"query":[{"key":"ComponentType","value":"NOTIONAL_POINT","description":"Type of component"}]},"description":"The report contains list of all the service points (receipt and delivery points), zones and pipeline segments currently registered under Part 24 of the Rules, for the capacity transfer and day ahead auction."},"status":"e-Hub is operational but downstream systems are not available.","code":500,"_postman_previewlanguage":"Text","header":[],"cookie":[],"responseTime":null,"body":""}],"_postman_id":"c5f7ebd3-edc7-4b90-8603-46bf9a08db25"}],"auth":{"type":"basic","basic":{"basicConfig":[]}},"event":[{"listen":"prerequest","script":{"type":"text/javascript","exec":[""],"id":"a651d4c1-8dad-47ba-832d-79fc1d6b0fd5"}},{"listen":"test","script":{"type":"text/javascript","exec":[""],"id":"9171853f-8cda-4499-8c11-233e7b22dc15"}}],"variable":[{"key":"default","value":"https://apis.preprod.aemo.com.au:9319/ws/gsh/capacity/v1"},{"key":"default1","value":"https://apis.prod.aemo.com.au:9319/ws/gsh/capacity/v1"},{"key":"default2","value":"https://apis.preprod.marketnet.net.au:9319/ws/gsh/capacity/v1"},{"key":"default3","value":"https://apis.prod.marketnet.net.au:9319/ws/gsh/capacity/v1"}]}